Owner’s manual, Installation, Continued – Vanguard Heating VMH3000TPSA User Manual

Page 9: Thermostat sensing bulb, Installation options, A. mounting heater to wall

Advertising
background image

9

107102

OWNER’S MANUAL

For more information, visit www.desatech.com

Thermostat
Sensing Bulb

Clamp

THERMOSTAT SENSING
BULB

The thermostat sensing bulb has been placed
inside the heater for protection during shipping.

Locating Thermostat
Sensing Bulb

1.

Remove front panel of heater (see Fig-
ure 2, page 3).

2.

Locate thermostat sensing bulb just
under burner assembly.

IMPORTANT:

Attach thermostat sensing

bulb to back of heater for proper operation.

Attaching Thermostat
Sensing Bulb

1.

Remove thermostat sensing bulb from
holders inside heater. Route through
slot opening in bottom of heater.

2.

Place clamp on thermostat sensing bulb
as shown in Figure 10. Clamp is pro-
vided in hardware package.

3.

Snap clamp into upper mounting hole
as shown in Figure 10. Mounting hole
is located on lower left edge on back
of heater. Make sure the thermostat
sensing bulb is pointing up.

Figure 10 - Attaching Thermostat
Sensing Bulb

INSTALLATION OPTIONS

There are three options for mounting
this heater.

A. Mounting heater to wall

B. Mounting heater to optional hearth base

C. Mounting heater to optional mantel

(some mantels require the hearth base)

A. MOUNTING HEATER
TO WALL

Mounting Bracket

The mounting bracket is located in the pack-
age tray. Remove mounting bracket from
tray.

Methods For Attaching Mount-
ing Bracket To Wall

Only use last hole on each end of mounting
bracket to attach bracket to wall. These two
holes are 16 inches apart from their centers.
Attach mounting bracket to wall in one of
two ways.

1.

Attaching to wall stud

2.

Attaching to wall anchor

Attaching To Wall Stud:

This method pro-

vides the strongest hold. Insert mounting
screws through mounting bracket and into
wall studs.

Attaching To Wall Anchor:

This method

allows you to attach mounting bracket to
hollow walls (wall areas between studs) or
to solid walls (concrete or masonry).

Decide which method better suits your needs.
Either method will provide a secure hold for
the mounting bracket.

Marking Screw Locations

1.

Tape mounting bracket to wall where
heater will be located. Make sure
mounting bracket is level.

Figure 11 - Mounting Bracket Clearances

Attaching Mounting Bracket
To Wall

Note:

Wall anchors, mounting screws, and

spacers are in hardware package. The hard-
ware package is provided with heater.

Attaching To Wall Stud Method

For attaching mounting bracket to wall studs

1.

Drill holes at marked locations using
9/64" drill bit.

2.

Place mounting bracket onto wall. Line
up last hole on each end of bracket with
holes drilled in wall.

3.

Insert mounting screws through bracket
and into wall studs.

4.

Tighten screws until mounting bracket
is firmly fastened to wall studs.

Continued

INSTALLATION

Continued

WARNING: Maintain minimum

clearances shown in Figure 12. If
you can, provide greater clear-
ances from floor and joining wall.

2.

Mark screw locations on wall (see
Figure 11).

Note:

Only mark last hole on each end

of mounting bracket. Insert mounting
screws through these holes only.

3.

Remove tape and mounting bracket
from wall.

18

3

/

4

"

Min.

11"

Min.

16"

Adjoining Wall

Only Insert Mounting

Screws Through Last

Hole On Each End

Floor