Troubleshooting 27, Operation summary – Whistler 2000 WATT User Manual

Page 15

Advertising
background image

TROUBLESHOOTING

27

PROBLEM: TV Interference

Problem

Solution

Electrical interference from

Add a Ferrite data line fil-

ter inverter.

on to the TV power cord.
This filter is available at
RadioShack, or other
electronic supply stores.
part number 273-105.

PROBLEM: Low or No Output Voltage

Problem

Solution

Using incorrect type of

Use true RMS reading meter

voltmeter to test output

See "For You Technical

voltage.

Types"
Section of this manual.

PROBLEM: Low Battery Alarm On All The Time

Problem

Solution

Input voltage below

Keep input voltage above

11 volts.

11 volts to maintain
regulation.

Poor or weak battery

Replace battery.

condition.
Inadequate power being

Use lower gauge wire. See

delivered to the inverter

“Wire Cable Gauges”

or excessive voltage drop.

section of this manual.

Keep wire length as short
as possible.

OPERATION SUMMARY

Avoid placing the inverter near sources of heat or in
direct sunlight.

When in use, make certain that the inverter is properly
ventilated.

Do not use the inverter near flammable materials,
fumes, or gases.

Always operate the inverter in accordance with the
instructions in this manual. Failure to do so may result
in property damage, personal injury, or loss of life.

While connecting the inverter to the power source,
make certain that the inverter is well removed from
any potential source of flammable fumes or gases.

Always ground the inverter before operating it.

In the event a continuous audible alarm or automatic
shut off, turn the inverter OFF immediately. Do not
restart the inverter until the source of the problem has
been identified and corrected.

26

Advertising
This manual is related to the following products: