Specification, 29 troubleshooting 28 – Whistler 2000 WATT User Manual

Page 16

Advertising
background image

SPECIFICATION

WHISTLER 1200 WATT INVERTER SPECIFICATIONS

Maximum Continuous Power……………………………1200 Watts
Maximum Surge Capability (Peak Power).......................2400 Watts
No Load Current Draw………………………………...............0.50 A
Waveform……………………………….............Modified Sine Wave
Operating Input Voltage Range…………….............10-15 Volts DC
AC Receptacle……………………..............Dual 3 Prong Grounded
Approximate Dimensions............................. 9.5” L x 8.5” W x 3” H
Approximate Weight………………...................………………..8 lbs

WHISTLER 2000 WATT

INVERTER SPECIFICATIONS

Maximum Continuous Power…………........................…2000 Watts
Maximum Surge Capability (Peak Power).......................4000 Watts
No Load Current Draw…………………………...............…....0.50 A
Waveform…………………………...............…..Modified Sine Wave
Operating Input Voltage Range………….................10-15 Volts DC
AC Receptacle…………………..................Dual 3 Prong Grounded
Approximate Dimensions….........................13” L x 10.5” W x 3” H
Approximate Weight………………..............………………….12 lbs

WHISTLER 3000 WATT

INVERTER SPECIFICATIONS

Maximum Continuous Power……………........................3000 Watts
Maximum Surge Capability (Peak Power).......................5000 Watts
No Load Current Draw……………………………...............…0.80 A
Waveform…………………………….................Modified Sine Wave
Operating Input Voltage Range………….............…10-15 Volts DC
AC Receptacle……………………..............Dual 3 Prong Grounded
Approximate Dimensions…….................... 16” L x 9” W x 6.25” H
Approximate Weight……………………....…………….............20 lb

29

TROUBLESHOOTING

28

Overload or High Temp LED on

Problem

Solution

Equipment has a high

Turn inverter power switch

start up surge.

OFF (O) and then ON (l)
again until the inverter
powers your appliance.
Repeat as necessary
to get your appliance
"started".

Battery voltage below

Recharge or replace

10 volts.

battery.

Equipment being operated

Use a higher capacity

draws too much power.

inverter or do not use this
equipment.

Inverter is too hot (thermal

Allow inverter to cool.

shutdown mode).

Check for adequate
ventilation. Reduce the
load on the inverter to
rated continuous power
output.

Advertising