Pro 36, Wall chimney hood, Planning information – Wolf Appliance Company Pro 36" (914) Wall Chimney Hood PWC362418 User Manual

Page 6

Advertising
background image

6

Dimensions in parentheses are in
millimeters unless otherwise specified.

Planning Information

Pro 36"

(914)

Wall Chimney Hood

M O D E L P W C 3 6 2 4 1 8 ( R )

Ducting for Pro wall
chimney hoods.

DUCTWORK INSTALLATION

THROUGH ROOF

24"

(610)

DEPTH OF HOOD

ROOF CAP OR REMOTE BLOWER

10"

(254) ROUND DUCT

SOFFIT OR CABINET

OR DUCT COVER

NOTE: VERTICAL DISCHARGE ONLY FOR PRO WALL CHIMNEY HOODS.

VERTICAL DISCHARGE

TRANSITION

14"W x 9

3

/

4

"D TO 10"

ROUND

7"H (INCLUDING FLANGES)

30"

TO

36"

(762–914)

COUNTERTOP

TO BOTTOM OF

VENTILATION HOOD

36"

(914)

STANDARD

FLOOR TO

COUNTERTOP

HEIGHT

18"

(457)

HEIGHT

OF HOOD

16

3

/

4

"

(425)

TOP OF WOOD

MOUNTING STRIP

WALL HOOD

D U C T I N G C O N S I D E R A T I O N S

Wolf Pro wall chimney ventilation hoods are

shipped without the blower assembly. Internal,

in-line and remote blower assemblies are

available.

IMPORTANT NOTE: Install this ventilation hood
only with a Wolf blower.

Wolf Pro wall chimney hoods have a vertical

discharge location with 10" (254) round duct.

A transition with backdraft damper is included.

The hood will operate most efficiently when

ductwork does not exceed 50' (15 m) in length.

Local building codes may require the use of

make-up air. Consult your local HVAC profes-

sional for specific requirements in your area.

IMPORTANT NOTE: Wolf Pro wall chimney

hoods must be vented to the outside. Use only

metal ductwork.

Refer to the illustration below for ducting

considerations for Pro wall chimney hoods.

Advertising