Model LG & LD Pool and Spa Heater

Page 19

6.

Use compressed air to blow out any standing

water remaining in the heat exchanger.

7.

Grease the threads on the drain plugs and rein-

stall plugs, but do not tighten.

8.

Disconnect the pressure switch from the siphon

loop (copper tubing) (see Figure 22).

3D-3. Spring Start-up

To restart the heater in the Spring, have a profes-

sional service technician reassemble the heater as

follows:
1.

Fill the siphon loop with approximately 5cc of

SAE 50, non-detergent oil. Attach the copper

tubing to the pressure switch (see Figure 22).

2.

Tighten the drain plugs.

3.

Turn on the filter pump and circulate water

through the heater for 5 minutes. Check for leaks

while circulating.

4.

Turn on the main gas supply valve to the heater,

outside the heater jacket.

5.

Turn on the heater following the lighting instruc-

tions found on the inside of the heater, or pages

17(LD) or 18(LG) of this manual.

3D. Seasonal Care

Caution

Do not operate this heater outdoors at

temperatures below 20 degrees Fahrenheit

(°F) (-7 degrees Celsius [°C]).

3D-1. Spring and Fall Operation

During periods when the pool is only going to be

used occasionally, turn the temperature control down

to the MIN setting. This prevents the pool from water

from becoming chilled, and minimizes the time re-

quired to raise the pool water back up to the desired

temperature.

In areas subject to only short freeze periods, turn

off the heater and run the pump continuously for the

length of the freeze period.

If the heater is not going to be used for a long

period of time, shut it down completely. Follow the

instructions found on the inside of the heater, or pages

17(LD) or 18(LG) of this manual.

3D-2. Winterizing

In areas where freezing temperatures occur in

winter, and the pool or spa will not be used, have your

service technician perform the following steps:
1.

Turn off the main gas supply valve to the heater,

outside the heater jacket.

2.

Remove heater door.

3.

Shut down the heater following the shutdown

instructions found on the inside of the heater.

4.

Remove the drain plug from the return header

(see Figure 21), loosen the drain plug from the

inlet/outlet header, and completely drain the

heater before the first frost.

5.

After all water has drained from the heater,

remove the drain plug from the inlet/outlet side.

Check for mineral buildup in the openings.

Figure 21. Heater drain locations.

Figure 22. Pressure switch copper tubing.