Waterpik Technologies LD User Manual

Page 4

Advertising
background image

Page 2

WATERPIK TECHNOLOGIES INC.

Gas-Fired Pool Heaters, ANSI Z21.56, and in Canada

with CAN1-4.7-M85.

Certain sections of this manual are specific to

either United States or Canadian installations, and are

labeled as such.

1B. Description

The Laars Lite 2 LD heater gets electrical power

from an external 120VAC or 240VAC source and

provides a dual thermostat Flex-Temp control system

for pool/spa combinations or preheat convenience. The

Laars Lite 2 LD heater also meets the California, New

York, Hawaii, and Oregon state energy requirements

for intermittent ignition gas appliances. The Laars Lite

2 LG heater is a self contained standing pilot unit and

requires no external power.

The Laars Lite 2 heater is specifically designed

for heating swimming pools and spas. Do not use it as

a general service water heater. There is a specially

designed model of Laars Lite 2 for heating salt water

pools. Consult your dealer for the appropriate

Waterpik Laars products for these applications.

1C. Warranty

The Laars Lite 2 heater is sold with a limited

factory warranty. Details are specified on the back

cover of this manual. A copy of the warranty and a

warranty registration card are included in the plastic

bag shipped with the heater. Fill out and return the

warranty registration card.

Make all warranty claims to an authorized

Waterpik Laars representative or directly to the

factory. Claims must include the heater serial number

and model (this information can be found on the rating

plate), installation date, and name of the installer.

Shipping costs are not included in the warranty cover-

age.

Damage caused by improper installation or

assembly, or to the heat exchanger by corrosive water,

is NOT covered by the Warranty. See Section 3D for

maintaining proper pool water chemistry.

NOTE: Keep this manual in a safe place for

future reference when inspecting or servicing the

heater.

1D. Technical Assistance

Consult Waterpik Laars or your local distributor

with any questions or problems involving the specifica-

tions, installation, and operation of your Waterpik

Laars equipment. An experienced technical support

staff is ready to assist in assuring the proper perfor-

mance and application of Waterpik Laars products.

For technical support call (415) 382-8220 extension

260.

SECTION 2.

Installation Instructions

2A. General Information

Install the Laars Lite 2 heaters, vent caps and

drafthoods in accordance with the procedures in this

manual, local codes and ordinances, and in accordance

with the latest edition of the National Fuel Gas Code,

ANSI Z223.1. In Canada, the installation must be in

accordance with CAN1-B149.1 or .2 and local codes.

The authority having jurisdiction may require that the

installation conform to the Standard for Gas-Fired

Heaters, ANSI Z21.56. Any changes to the heater, gas

controls, gas orifices, wiring, draft diverter, or im-

proper installation may void the warranty. If field

conditions require change to any of the above, consult

the factory.

All gas-fired products require correct installation

to assure safe operation. The requirements for pool

heaters include the following:

1. Field assembly (if required)

2. Appropriate site location (clearances) and

flooring

3. Sufficient combustion and ventilation air

4. Properly sized gas meter and piping

5. Proper electrical wiring (if required)

6. Adequate water flow
This manual provides the information needed to

meet these requirements. Review all application and

installation procedures completely before continuing

the installation.

2B. Field Assembly

The Laars Lite 2 heater is shipped from the

factory with the top assembly in the low-profile

configuration for outdoor installation in the U.S. In

Canada, an outdoor installation requires the addition of

a factory approved vent cap. The Laars Lite 2 heater is

design certified for indoor installation when equipped

with a drafthood, which must be installed without

modification.

The Laars Lite 2 heater is also certified for

installation in an outdoor shelter in Canada when

equipped with a drafthood. An outdoor shelter is an

enclosure not normally occupied which does not

communicate directly with occupied areas.

Check the rating plate on the heater or the Parts

List (Sec. 4) of this manual for the correct Waterpik

Laars drafthood or vent cap part number. See instruc-

tions supplied with the drafthood or vent cap for

installation and attachment. When the drafthood is

used, locate the heater so as to be in the same atmo-

spheric pressure zone as the combustion air inlet to the

heater.