Multi-Function Cooktop Specifications

7

wolfappliance.com/specs

Gas Supply Requirements

GAS MANIFOLD PRESSURE

Natural Gas: Standard orifices are set for 5"

(12.5 mb)

WC (water column).

LP Gas: Standard orifices are set for 10"

(25 mb)

WC.

Gas Supply Pressure: The maximum gas supply

pressure to the regulator should never exceed 14"

(34.9 mb)

WC; .5 psi

(3.5 kPa)

for natural and LP gas.

The minimum line pressure is 7"

(17.5 mb)

WC for

natural gas and 11"

(27.4 mb)

WC for LP gas.

Gas Pressure Regulator: To control and maintain a

uniform gas pressure in the gas manifold, the unit must

be used with a gas pressure regulator. The burner

orifices, etc. are sized for the gas pressure delivered by

the supplied regulator. Do not remove the regulator.

The maximum gas supply pressure to the regulator

should never exceed 14"

(34.9 mb)

WC; .5 psi

(3.5 kPa)

.