Multi-function cooktop specifications, Electrical requirements – Wolf Appliance Company IM15 User Manual

Page 8

Advertising
background image

Multi-Function Cooktop Specifications

8

Electrical Requirements

The Wolf multi-function cooktop requires a 120 V AC,

60 Hz, 15-amp, fused electrical supply. A time-delay fuse

or circuit breaker is recommended. It is recommended that

a separate circuit serving only this appliance be provided.

A ground fault circuit interrupter (GFCI) is not recom-

mended and may cause interruption of operation.

ELECTRICAL GROUND

The 6'

(1.8 m)

power cord is equipped with a 3-prong,

grounding plug for protection against shock hazard. The

power cord must be plugged into a mating 3-prong

grounded outlet, grounded to conform with the National

Electrical Code, ANSI/NFPA 70 latest edition, or Canadian

Electrical Code (CSA) and all local codes and ordinances.

Refer to the illustration below.

IMPORTANT NOTE:

This appliance must be properly

grounded to avoid electrical shock hazard. Do not ground

to a gas pipe.

GROUNDING

PLUG

GROUNDED

ELECTRICAL OUTLET

Electrical ground.

ELECTRICAL SHOCK HAZARD: Plug into a grounded

3-prong outlet. Do not remove ground prong. Do not

use an adapter. Failure to follow these instructions can

result in electric shock, fire or death.

N

A

1

1

2

2

BLACK

BLACK

WHITE

WHITE

RED

WHITE

RED

WHITE

RED

SPARK
MODULE

3 CONDUCTOR
POWER CORD

GRN

BLK

IMPORTANT NOTE:

Electronic ignition systems operate

within wide voltage limits, but proper ground and polarity

are necessary. In addition to checking that the electrical

outlet provides 120 V AC power and is correctly grounded,

the outlet must be checked by a qualified electrician to

see if it is wired with correct polarity.

WIRING DIAGRAM

The wiring diagram below covers the control circuit for the

Wolf multi-function cooktop.

Wiring diagram.

Advertising