TROUBLESHOOTING SUGGESTIONS

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

No power to warmer

Circuit breaker off or tripped

Reset circuit breaker

Unit not plugged in

Make sure unit is plugged in to
power receptacle

Warmer will not heat

Temperature control not set

Set control to desired temperature

Internal damage

Contact you Authorized Wells
Service Agency for repairs

Autofill does not add water to
warmer

Water supply not turned on

Turn on water supply

Internal damage

Contact your Authorized Wells
Service Agency for repairs

Warmer overflows (Autofill does
not shut off water fill)

Scale build-up on water level
probe

Clean water level probe with delime
cleaner

Internal damage

Contact your Authorized Wells
Service Agency for repairs

Warmer trips circuit breaker

Tank leaking or other internal
damage

Contact your Authorized Wells
Service Agency for repairs

Internal damage

Contact your Authorized Wells
Service Agency for repairs

Mineral deposits on tank acting
as a insulator

Clean tank with delime cleaner

Connected to wrong voltage

Verify supply voltage - must match
voltage on warmer nameplate

Too much water

Remove water from pan until 1” of
water remains in tank

Warmer slow to heat

021

303

333

Op

M

anual for

Built-In

Bain M

a

rie
W
a

rmer

s

There are no user-serviceable components in this appliance.
In all instances of damage or malfunction, contact your Authorized Wells Service Agency for repairs.