3. For “top-mounted” installation:


a. Verify that provided sealants are applied to the underside of

the warmer top flange prior to setting the unit into the cutout.

b. After installation, verify that the tabs on the Wellsloks are

turned out to lock the warmer into the counter.

c. Apply a thin bead of food-grade silicone sealant around the

flange to seal it to the counter.

d. Wellslok extension kits are available for installing warmers in

counter tops where the standard Wellslok would not normally

reach. The extension kit will adapt to counter tops up to

1¾” thick.

e. For heated tanks installed in plastic (e.g. Corian®) counter

tops, the counter material must be protected from the heat of

the warmer in order to prevent discoloration and/or

deterioration. Wellsloks are not suitable for this purpose.

The installer should contact the manufacturer or distributor of

the countertop material for specific installation instructions.


D. ELECTRICAL INSTALLATION


1. Refer to the nameplate. Verify the electrical service power.

Voltage and phase must match the nameplate specifications.

Wiring the warmer to the wrong voltage can severely damage the

unit or cause noticeably decreased performance.


2. Available electrical service amperage must meet or exceed the

specifications listed on the provided specification sheet .


3. Warmer and control unit must be connected to an appropriate

building ground. Ground connection will be marked “GND” or “ ” .


E. PLUMBING

INSTALLATION

For use in the State of Massachusetts, this appliance must be

installed in compliance with Massachusetts Fuel Gas and

Plumbing Code CMR 248.


1. IMPORTANT:

All plumbing installations must be performed by a qualified

plumber.


2. Some jurisdictions may require an approved back-flow preventer

in the drain line. It is the responsibility of the plumber to determine

such requirement, to provide the proper back-flow prevention

device, and to properly install the required back-flow preventer.


3. For AUTOFILL units: Some jurisdictions may require an

approved back-flow preventer in the water supply line. It is the

responsibility of the plumber to determine such requirement, to

provide the proper back-flow prevention device, and to properly

install the required back-flow preventer.

Autofill supply must be connected to a COLD WATER line only.

INSTALLATION (continued)

021

303333

OpM

anual

for

Buil

t-In

B

a

in M

a

rie

W

a

rmer

s

NOTE: Damage caused by
leaks due to improper
installation is NOT covered by
warranty.

CAUTION:

SHOCK HAZARD

The ground lug of this
appliance must be connected
to a suitable building ground.

IMPORTANT:
Contact a licensed electrician
to install and connect
electrical power to the
appliance.


IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.


IMPORTANT: Electrical
installation other than as
specified on the specification
sheet will void the UL listing,
and may void the warranty.

NOTE: Plumb connections
must be made in compliance
with all Federal, State and
Local Plumbing Codes and
Ordinances.