NOTE:

1) The cylinder must be provided with a shut off valve terminating in a LPG

supply cylinder valve outlet specified, as applicable, for connection NO 510 in
the standard for compressed gas cylinder valve outlet and inlet connections,

ANSI/CGA-v-1.

2) The cylinder supply system must be arranged for vapor withdrawal.
3) The cylinder used must include a collar to protect the cylinder valve.

Annually check operation:
A. Open the door panel.

B. Open the propane tank valve.

C. Spoon several drops (or use squirt bottle) of the soapy solution onto gas hose

connection and pilot connection.
D. Inspect the connections and look for bubbles.

E. If no bubbles appear, the connection is safe.

F. If bubbles appear, there is a leak. Close the propane tank valve and loosen and
re-tighten this connection.

G. Check for leaks again.

H. If bubbles still appear, close the propane tank valve and call you gas
supplier. DO NOT attempt to use the heater.



WARNING: DO NOT attempt to operate the heater until you have read
and understand all precautions. Failure to do so can result in serious

personal injury, death or property damage.

Before Turning Gas Supply ON:
Your heater was designed and approved for OUTDOOR USE ONLY. DO NOT use

it inside a building or any other enclosed area.


Make sure surrounding areas are free of combustible materials such as gasoline

and other flammable vapors or liquids.


Ensure that there is no obstruction to air ventilation.

Be sure all gas connections are tight and there are no leaks


Be sure the access panel is clear of debris.

Be sure any component removed during assembly or servicing is replaced and
fastened prior to starting.