1. INTRODUCTION

The Unity Sync Data option card provides an IRD with a synchronous data channel output. This
data stream is carried in transport packets whose PID may be assigned in the Wegener UMX4025
at the uplink. This data appears bit-serial on either an RS422 or LVDS output port. The RS422
and LVDS can be activated one at a time or simultaneously.

2. INSTALLATION

2.1 Option Card Install

1. Power-down UTY4000 and remove top cover. Do not lose special screws.

2. See Figure 1, page 5.

3. Expansion module may be installed into either inboard (Module 1) or outboard

(Module 2) position.

3. Remove block-out plate for selected position. Save hardware.

4. Install PWB into selected position. Take precautions against Electro-static

discharge to avoid damage to module.

5. Connect supplied 24-pin cable from J13 on the motherboard to J1 on the Sync Data

Option card.

6. Set jumpers on option card: J9 is the only jumper configurable by the user. If the

sync data card is installed as module 1, place J9 in the dotted position. If the sync
data card is installed as module 2, place J9 in the non-dotted position.

7. Power-up unit and verify that installed option is recognized under

Status_Reports\Parameter_Status menu.

8. Power-down unit and re-install cover.