Control and status indications – Wegener Communications Unity Satellite Receiver Model Unity Synchronous Data Option User Manual

Page 3

Advertising
background image

3

UTY4000-007

2.2 Customer Premises Wiring

Outputs supplied on two RJ45 jacks. Pins are numbered (left-to-right) 1 to 8 as seen
from the open end with tab facing downward.

PIN#

LVDS SIGNAL

OUTPUT

RS422 SIGNAL

OUTPUT

1

GND

GND

2

LD+

RD+

3

LD-

RD-

4

LS+

RS+

5

LS-

RS-

6

LC+

RC+

7

LC-

RC-

8

GND

GND

Table 1. RJ-45 Pin-outs

3. CONTROL AND STATUS INDICATIONS

Note: Sync Data option card may be setup by your network and local control may be disabled. If
so, only the status monitoring will be possible.

3.1 From Terminal

Ÿ Sync data card setup with local control disabled:

The sync data card setup cannot be accessed via the terminal with local control
disabled. Local control will have to be authorized by the network.

Ÿ Sync data card setup with local control enabled :

CSD cmd param port
Cmd: R - Set RS422 output state

L - Set LVDS output state

D - Set data rate

P - Set PID

Param:E/D - Enable/disable output ports (used with R & L commands)

64.0 - 6875 Kbps - data rate range (used with D command)

0x0020 - 0x1FFE - PID range (used with P command)

Port: port number (1 or 2)

Ÿ

Sync data card status

Advertising