INSTALLATION START-UP AND CHECKOUT


Before turning on power or water to Water-Max II™, verify:

a. Unit is level, with all legs touching the counter
b. Water and electrical connections properly made
c. HEATER SWITCH is

OFF

( O )

d. Removable SATELLITE is NOT installed on Water-Max II™ at this

time


Only after steps a. through d. are satisfactorily completed:

e. Turn on water supply valve to Water-Max II™.
f.

Turn on electric power to unit. Green POWER light must be off.
Water will automatically start filling the internal tank.

g. WAIT at least 4 minutes. The internal tank fill solenoid must shut

off before proceeding.

h. Once internal tank fill solenoid shuts off, verify water in tank by

opening DRAIN VALVE momentarily. Water must be present at
drain valve.


Once satisfied that the heater tank is filled:

i.

Press the HEATER SWITCH to

ON

( I ). Green POWER light will

glow. Water in the heater tank will begin heating and the amber

HEAT light will glow.

Approximately 15 - 20 minutes after energizing the heater, HEAT

light will turn off, indicating water in the tank has reached the

setpoint

temperature.

j.

Press the HEATER SWITCH to

OFF

( O )

Be sure the COVER is properly installed on the SATELLITE.

Install SATELLITE on Water-Max II™ shelf.

Press the HEATER SWITCH to

ON

( I ). Amber REFILL light will

glow and hot water will begin filling the satellite after 15 - 20

seconds.
k. Satellite tank will fill completely within 30 minutes.

CAUTION:

Hot Surface

Exposed surfaces can be hot
to the touch and may cause
burns.


CAUTION

Burn Hazard

Water in Water-Max II™ is
EXTREMELY HOT!

CAUTION

SCALDING
HAZARD

Place satellite tank on
dispenser as soon as the
main tank is at temperature
(i.e. READY light lit).
Failure to do so may result
in steam splattering when
satellite is installed and
satellite filling begins.


IMPORTANT:
DO NOT energize the
HEATER SWITCH until the
heater tank is filled. Damage
to the heating element will
occur. Such damage is NOT
covered under warranty.

INSTALLATION (continued)