TROUBLESHOOTING SUGGESTIONS

There are no user serviceable components in the appliance. In all cases of damage or component
malfunction, contact your Authorized Wells Service Agency for repairs.

14

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

Power light not lit

Circuit breaker off or tripped

Reset circuit breaker

Satellite does not fill

Satellite not properly positioned
on shelf

Set satellite in proper position

Low water in main tank

Verify water supply is fully on

Inlet solenoid strainer plugged -
clean strainer

Internal damage - contact
Authorized Wells Service Agency

Satellite suffers excessive fill time Improper internal adjustments

Contact Authorized Wells Service
Agency

Dispensed water not hot enough

Satellite not properly positioned
on shelf

Set satellite in proper position -
verify connector securely seated

Water temp thermostat not set

Contact Authorized Wells Service
Agency

Dispense thermostat set too low

Main tank does not heat

Tripped circuit breaker

Contact Authorized Wells Service
Agency

Internal damage