Pro hood liner installation, Hood wiring connections, Hood liner installation – Wolf Appliance Company L342212 User Manual

Page 10

Advertising
background image

Pro Hood Liner Installation

10

Before making electrical connections, make sure the

electrical power is turned off at the service panel.

Hood Wiring Connections

BLOWER WIRING

IMPORTANT NOTE:

Refer to specific installation instruc-

tions provided with each blower assembly for additional

mounting and wiring instructions.

1) Remove the hood electrical box cover from the back of

the hood liner. Run Romex

®

wire from the service panel

to the hood installation location. Insert the Romex

®

wire through the holes in the back of the hood liner to

the electrical box. Refer to the illustration below for the

location of wiring.

2) Using the wire connectors provided, connect black

wire to power supply black wire, white wire to power

supply white wire and green wire to green wire or bare

wire.

3) Place all wiring connections inside the electrical box

and reinstall the cover. Make sure all wires are secure

and that no wires are pinched between the cover and

electrical box.

Hood Liner Installation

The filters must be removed from the hood liner prior to

installation. Refer to hood liner preparation on the previous

page.

Position the hood liner in the desired location on the wall.

Install #10 x 2"

(59)

screws through the mounting holes on

the back plate. Verify that the screws engage the wall

studs or blocking.

If additional support is required for the hood liner, drill

supplementary mounting holes in the back plate and use

these holes to attach the hood liner to wall framing.

Due to the weight of the hood, be sure to have

adequate assistance for installation.

1

7

/

8

"

(48)

3

1

/

2

"

(89)

12

1

/

2

"

(318)

Location of hood wiring.