Pro Hood Liner Installation

8

Install Ductwork

IMPORTANT NOTE:

Pro ventilation hood liners must

exhaust to the outdoors.

Wolf recommends that the ventilation hood be installed

30"

(762)

to 36"

(914)

above the countertop. Consult a qual-

ified HVAC engineer for specific ducting applications.

A 10"

(254)

round duct is recommended for pro ventilation

hood liners. Use only rigid metal ductwork, do not use flex

ducting.

Decide where the ductwork will run between the hood liner

and the outside. Pro hood liners have a vertical discharge.

A straight, short duct run will allow the ventilation hood to

perform most efficiently. Limit the number of elbows and

transitions. The duct run should be no longer than 50'

(15 m)

. There is a possibility of noise issues, if a remote

blower is used with a short duct run.

Unless you are using a remote blower, a roof or wall cap

must be installed. Connect 10"

(254)

round metal ductwork

to the cap and work back towards the hood. Use duct

sealing tape to seal joints between ductwork sections.

Pro hood liners have a backdraft damper included in the

transition assembly. Local codes may require the use of an

additional backdraft damper. Contact your local HVAC

professional for specific requirements. In cold weather

installations, a backdraft damper is necessary to minimize

the backflow of cold air into the room.

Local building codes may require the use of make-up air.

Consult your local HVAC professional for specific require-

ments in your area.

PRO HOOD LINERS

To reduce the risk of fire, use only metal ductwork.

DUCTWORK INSTALLATION

THROUGH ROOF

30"

(762) TO

36"

(914)

BOTTOM OF

HOOD TO

COUNTERTOP

12"

(305)

LINER HEIGHT

22

1

/

2

"

(572)

LINER DEPTH

12"

(305)

4"

(102)

DECORATIVE HOOD