Chapter 5 useful examples – Wasp Bar Code CCD - 80SIR User Manual

Page 19

Advertising
background image

29

4.5 Other parameters

These parameters include power up tone and LED indicator.

Power up Tone

* On

Off

LED Indicator

* LED on

Good read off

LED off

Good read on

4.6 Code(S) Single or Double Read

Code(S)

Single Read

Double Read

CHAPTER 5 USEFUL EXAMPLES

Here we list examples concerning configuration steps
for your reference. We have illustrated the steps for
defining code mark. Now we try others and you will
see that it's very important and very useful of our
ASCII Code Table and Decimal Table shown in
Appendix A and Appendix B respectively.

Please do remember one thing , that is -
everytime before setting up your own definition,
you will have to write down the order of
characters/digits that you find out from ASCII
Code Table/Decimal Table first. This important
step will minimize mistakes when you proceed
configuration procedures.

Now simply follow the following steps:
1) From Appendix A. ASCII Code Table you may find
out that:
- " 4" & " 1" stand for A
- "6" & "A" stand for j
- " 5" & " 8 " stand for X
Please take note, in orders, "4", "1", "6", "A", "5", "8"
2) Scan " START" label printed in the front cover of
manual.
3) Scan the provided pre-amble label.
4) Follow the order of "4", "1", "6", "A", "5", "8" to scan
the bar code in the Appendix D. Hex-Label Table.
5) Then scan " EXIT" label also printed in Appendix D.
Hex-Label Table.
6) Finally, scan "END" label printed in the front cover
in order to complete your own configuration.

The defaults of minimum and maximum length are 4
and 48 respectively. If you want to set 8 for minimum
and 20 for maximum, the steps will be as below:

1) Refer to Appendix B. Decimal Table you may find
that :
- " 08 " stands for 8
- " 14 " stands for "20"
Please take note, in orders, "0", "8", "1", "4"
2) Scan " START" label printed in the front cover of
manual.
3) Scan the provided variable length of bar code
label.
4) Follow the orders you write down to scan bar code
labels from Appendix D. Hex-Label Table..
5) Scan " EXIT" label also printed in Appendix D.
Hex-Label Table.
6) Scan " END" label printed in front cover to
complete your configuration.

Example 1. To setup pre-amble,

let's say AjX, of any code

Example 2. To set variable length

for code ITF 2/5

30

Advertising