Wells WVOC-4HS User Manual

Page 5

Advertising
background image

ITEM

1.

a6.


8.

9.

a10.

a11.

12.

a15.

16.

18.

19.

22.

23.

28.

a31.

38.

40.

41.

42.

43.

44.

53.

56.

58.

70.

DESCRIPTION

NAMEPLATE

FIRE SUPPRESSION
AGENT TANK (1.5 gal.)

ADJUSTABLE (FRONT) LEG

RIGID (REAR) CASTER

MANUAL PULL STATION

FUSIBLE LINKS

LOWER REAR ACCESS
PANEL

DISCHARGE NOZZLE

GREASE BAFFLE

PRE-FILTER ASSEMBLY

HEPA/CHARCOAL FILTER
PACK

GREASE CUP

GREASE TROUGH

VENTILATOR EXHAUST
DUCT

STATUS INDICATOR

POWER CORD

FUSES

POWER CONTACTOR

BUILDING FIRE ALARM
RELAY

GROUND LUG

INTERLOCK TERMINAL

FILTER INTERLOCK
SWITCHES

VENTILATOR FAN

SIDE SPACERS

COOLING FAN

COMMENT

Gives Manufacturer, Model and Serial Number information.
Also lists electrical specifications.

Container for Ansulex™ Low-pH liquid fire suppression liquid.

Allows the unit to be leveled.

Allows the unit to be easily positioned by lifting the front of the unit
slightly.

Provides a means of manual activation of the fire suppression system.
PULL ONLY IN CASE OF FIRE!

Automatically activates fire suppression system in the event of fire on
the cooktop.

Allows access to Ansul® fire suppression agent tank (a6) and controls
also access to main power contactor (41).

Fire suppression media discharges here (2 places).

Extracts and drains most grease and moisture from the air flow.

Comprises the PRE-FILTER FRAME and a replaceable
PRE-FILTER. Stops larger particles of grease from reaching the
FILTER PACK for reduced maintenance costs.

Stops most grease and smoke particles. Also assists in some cooking
odor removal.

Collects grease/moisture drained from grease trough (23).

Directs grease/moisture removed by grease baffle to grease cup.

Exit point for ventilator airflow - on top left rear of unit.
DO NOT BLOCK

Displays status of fire suppression system (COCKED - FIRED) If
FIRED, a buzzer will sound continuously.

6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).

Provide over-current protection of cooking appliance.

Energizes cooktop only while ventilator section is sensed as
operational.

Reports fire alarm condition to building fire management system.

Ground wire of power cord connects here.

Provides connection for shut-down control by building fire
management system.

Proper installation of grease baffle and filter pack close these switches
in ventilator sensor circuit. Provides air movement for ventilation.

Provides air movement for ventilation.

Maintain required 6: spacing from combustible surfaces.

Provides cooling for cooktop controls.