11

Dimensions in parentheses are in
millimeters unless otherwise specified.

I N S TA L L AT I O N

I N S T R U C T I O N S

U N F R A M E D

M O D E L C T 3 6 E U

The illustrations below provide installation
specifications for Model CT36EU.

For ease of installation, 39" (991) cabinets are
recommended for installation of Model CT36EU.

A Wolf 36" (914) built-in single oven may be
installed below Model CT36EU. For this installa-
tion, unless you are using cabinets deeper than
24" (610), it is recommended that the electrical
supply be placed in the base cabinet to the right
of the oven. Refer to installation instructions
provided with the built-in oven for additional
specifications.

If Model CT36EU is installed above cabinets,
electrical placement is not critical. A grounded
electrical box should be located within 4'
(1.2 m) of the right rear of the cooktop.

For Model CT36EU installation options, refer
to Unframed Installations on pages 12–13.

IMPORTANT NOTE: For flush mount applica-
tions, it is recommended to measure the
cooktop glass before cutting the countertop to
ensure a proper fit. Small variances may exist
between the template and the cooktop.

2"*

min (51)

CUT-OUT TO

COMBUSTIBLE

MATERIALS

(BOTH SIDES)

18"

(457)

36"

(914)

STANDARD

FLOOR TO

COUNTERTOP

HEIGHT

30"

(762)

COUNTERTOP TO

COMBUSTIBLE

MATERIALS

ABOVE COOKTOP

*Minimum clearance from both side edges and back edge of cooktop cut-out to combustible materials up to 18" (457) above countertop.

39"

(991)

RECOMMENDED CABINET WIDTH

36"

min (914)

36-INCH OVEN OPENING

36

1

/

8

"**

(918)

RECESSED AREA FOR

FLUSH MOUNT INSTALLATION ONLY

34

3

/

8

"

(873)

COOKTOP CUT-OUT WIDTH

1

5

/

16

"

(33)

RADIUS

FRONT OF COUNTERTOP

2

7

/

16

"

(62)

19

3

/

8

"

(492)

COOKTOP

CUT-OUT DEPTH

1

9

/

16

"

(40)

21

1

/

8

"**

(537)

RECESSED AREA

FOR FLUSH MOUNT

INSTALLATION ONLY

7

/

16

"

(11) RADIUS

**Minimum dimension, but may be exceeded by up to

1

/

8

" (3).

RECESSED AREA FOR

FLUSH MOUNT INSTALLATION ONLY

5

/

16

"

(8)

7

/

8

"

(22) max

COUNTERTOP

PROFILE

SEE COUNTERTOP

CUT-OUT BELOW

13"

max

(330)

24"

min

(610)

SEE COUNTERTOP

CUT-OUT BELOW

2"*

(51)

4"

min

(102)

E

10"

(254)

4"

min

(102)

TO OVEN

OPENING

3

1

/

2

"

(89)

4

1

/

2

"

(114)

Overall Dimensions

Countertop Cut-Out

21"

(533)

OVERALL

DEPTH

36"

(914)

OVERALL WIDTH

5

1

/

2

"

(140)

4

1

/

4

"

(108)

CONDUIT

M O D E L C T 3 6 E U

Overall Width

36" (914)

Overall Height

4

1

/

4

" (108)

Overall Depth

21" (533)

Minimum Cabinet Depth

22

3

/

4

" (578)

Minimum Height Clearance* 4

1

/

2

" (114)

Cut-Out Width

34

3

/

8

" (873)

Cut-Out Depth

19

3

/

8

" (492)

I N S T A L L A T I O N S P E C I F I C A T I O N S – M O D E L C T 3 6 E U

*Minimum 6

1

/

4

" (159) clearance is required

between countertop and any combustible
surface directly below the cooktop.

For detailed conduit dimensions, refer to
the illustration on page 5.

Dimensions may vary to ±

1

/

8

" (3).

Advertising