Wolf Appliance Company CT15E User Manual

Page 6

Advertising
background image

6

E

4"

(102)

15"

(381)

15"

(381)

2"*

min (51)

CUT-OUT TO

COMBUSTIBLE

MATERIALS

(BOTH SIDES)

13

3

/

8

"

(340)

COOKTOP CUT-OUT

WIDTH

13

3

/

8

"

(340)

COOKTOP CUT-OUT

WIDTH

33"

(838) RECOMMENDED

CABINET WIDTH

18"

(457)

NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457)
recommended cabinet width for installation of single 15" (381) cooktop or module. *Minimum clearance from both side edges of cooktop cut-out
to combustible materials up to 18" (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 18" (457) above countertop.

19

1

/

4

"

(489)

COOKTOP CUT-OUT

DEPTH

2

1

/

2

"

min

(64)

36"

(914)

STANDARD

FLOOR TO

COUNTERTOP

HEIGHT

13"

max

(330)

30"

(762)

COUNTERTOP TO

COMBUSTIBLE

MATERIALS

ABOVE COOKTOP

FRONT OF COUNTERTOP

2

1

/

2

"

min

(64)

19

1

/

4

"

(489)

COOKTOP

CUT-OUT DEPTH

2"**

(51)

Overall Dimensions

Countertop Cut-Out

21"

(533)

OVERALL

DEPTH

15"

(381)

OVERALL WIDTH

5"

(127)

3

3

/

4

"

(96)

CONDUIT

M O D E L C T 1 5 E

Overall Width

15" (381)

Overall Height

3

3

/

4

" (96)

Overall Depth

21" (533)

Minimum Cabinet Depth

22

3

/

4

" (578)

Minimum Height Clearance*

4" (102)

Cut-Out Width

13

3

/

8

" (340)

Cut-Out Depth

19

1

/

4

" (489)

I N S T A L L A T I O N S P E C I F I C A T I O N S – M O D E L C T 1 5 E

F R A M E D

M O D E L C T 1 5 E

The illustrations below provide installation
specifications for Model CT15E.

If Model CT15E is installed above cabinets, the
electrical placement is not critical. A grounded
electrical box should be located within 4'
(1.2 m) of the right rear of the cooktop.

For installation above an oven, unless you are
using cabinets deeper than 24" (610), it is
recommended that the electrical supply be
placed in the base cabinet to the right of the
oven.

W O L F

E L E C T R I C C O O K TO P S

IMPORTANT NOTE: Do not block the cooling
fan located at the bottom of the cooktop.

*Minimum 5

3

/

4

" (146) clearance is required

between countertop and any combustible
surface directly below the cooktop.

For detailed conduit dimensions, refer to
the illustration on page 5.

Dimensions may vary to ±

1

/

8

" (3).

Advertising