Wegener Communications 6420 User Manual

Page 16

Advertising
background image

iPump 6420 User’s Manual

www.wegener.com

800070-01 Rev B

Chapter 1, Page 12

Figure 1-3: iPump6420 Functional Block Diagram

DVB Receiver

subsystem

Transport Demux

Audio Decompression

module #1:

Wave-PCM, mp2,

or mp3 (option)

MPEG Transport

Audio Decompression

module #2:

Wave-PCM, mp2,

or mp3 (option)

Audio Decompression

module #3:

Wave-PCM, mp2,

or mp3 (option)

Local Controller

(Supports Compel, web,

terminal, & FP cntl)

Compel

Selected Progr/

Audio stream

Audio re-sampler

& Mixer

Audio
Output n of 2

Cue Relay

Closures

RBDS serial

Data output

Local PIO

(closure) inputs

WAN & LAN

Ethernet adaptors

Flash Storage:

Software & settings

Terminal

Serial port

Cue relays,
Bank n of 2

RBDS
Output n of 2

Logically considered

“Port n of 2”

Alarm relay

RF

Input

Serial
M & C

Alarm relay
closure

Incoming
closures

WAN

LAN

HDD Storage:

Media, playlists,

schedules, OAR

recordings, logs

Internal
Control

POTS Modem

(option)

Analog
telco line

AM/FM

Tuner (option)

AM/FM radio
antenna
input n of 2

mp3 codec

(option)

Front-Panel

LCD/Keypad/LEDs

Advertising