Ratings

17a

Part No. 550-141-705

31

I=B=R Burner

✝ ✝

Boiler Water

Capacity

Net I=B=R Ratings

Content Gals.

Packaged

✝ ■

* *

Positive

Boiler

* *

Gross

Net

Stack

Presure

I=B=R

Weight

Light

❍ ■

I=B=R

Firebox

Gas

In

Vent

Steam

Less

Oil

Gas

Output

Steam

Steam

Water

Boiler

Volume

Volume

Firebox

Dia.

to

Water

Boiler Model

GPH

MBH

MBH

Sg. Ft.

MBH

MBH

H.P.

Cu. Ft.

CFM

In. W.C.

Inches

Water

Waterline

Lbs.

▲ -378- *F ●

2.40

346

278

871

209

242

8.3

2.61

139

0.22

8

37.5

27.5

1355

▲ -478- *F ●

3.40

494

400

1250

300

348

11.9

3.97

198

0.22

8

49.0

36.0

1615

▲ -578- *F ●

4.45

641

521

1629

391

453

15.6

5.33

259

0.21

8

60.5

44.5

1875

▲ -678- *F ●

5.50

789

643

2008

482

559

19.2

6.69

320

0.21

8

72.0

53.0

2130

▲ -778- *F ●

6.50

937

7642388

573

66422.8

8.05

378

0.21

10

83.5

61.5

2390

▲ -878- *F ●

7.50

1084

886

2771

665

770

26.4

9.41

436

0.20

10

95.0

70.0

2650

▲ -978- *F ●

8.50

1232

1007

3154755

876

30.1

10.77

4

940.20

10

106.5

78.5

2910

▲ -1078- *F ●

9.60

1379

1129

3533

847

982

33.7

12.13

558

0.20

10

118.0

87.0

3165

▲ -1178- *F ●

10.60

1527

1250

3917

938

1087

37.3

13.49

616

0.19

10

129.5

95.5

3425

▲ -1278- *F ●

11.60

1674

1372

4321

1039

1193

41.0

14.85

675

0.19

12

141.0

104.0

3680

▲ Use prefix “BL” for light oil, “BG” for gas, “BGL” for gas-light oil, or “H” for boiler only for use with approved burners. Add prefix “A” to designator

for factory-assembled 78 (ABL-478). Substitute “P” for “B” for fire-tested package unit (PL-478).

*

Substitute “S” for steam, “W” for water.

For T-intermediate section(s) and tankless heater(s) add suffix “(number required) TIH”; for T-intermediate section(s) with cover plate(s) only add suffix “(number
required) TIP”.

Burner input based on maximum of 2,000 feet altitude - for higher altitudes consult a Weil-McLain representative.

** No. 2 fuel oil - Commercial Standard Spec. CS75-56. Heat value of oil - 140,000 Btu/Gal.

Consult Weil-McLain BURNER SPEC AND DATA SHEET for gas pressures required.

MBH refers to thousands of BTU per hour.

Gross I=B=R ratings have been determined under the I=B=R provision governing forced draft boiler-burner units.

✝✝ Net I=B=R ratings are based on net installed radiation of sufficient quantity for the requirements of the building and nothing need be added for normal piping and

pick-up. Water ratings are based on a piping and pick-up allowance of 1.15. Steam ratings are based on the following allowances: 378 through 1178 - 1.333; 1278
- 1.321. An additional allowance should be made for gravity hot water systems or for unusual piping and pick-up loads. Consult a Weil-McLain representative.

*** Stack gas volume at outlet temperature.

With 0.10" W.C. positive at flue collar.

Note: Sections tested for 80 PSIG working pressure.