Discharge pump installation a b, Main drain pipe, Optional) – Whirlpool Petra Collection User Manual

Page 15

Advertising
background image

Main Drain Pipe

ON/OFF DISCHARGE SWITCH

L-TRAP

DISCHARGE PUMP

POWER CORD

CONVERTER BOX

Check Valve must be installed to prevent back flow

Tub

- Outlet from drain pump must be placed

on top of the main drain pipe

- Do not use flexible pipe for drain

Outlet

FAQ

1) Pump hums but does not drain the water out

- Air Lock : Piping elevation must be above discharge pump outlet

so that air can be released

- Turn pump on, wait 5 seconds, turn pump off. Repeat 10 times. If the air is not repleased,

detach attachment pipe and re-attach

Quick Tip: Use a plunger to release the air lock

2) Pump does not turn on

- Check the power source
- Check if the air tubing is properly attached from the switch to the converter box

- Check attachment pipes throughly for debris

3) Noise when turn on

- Foreign object may be lodged - Disassemble and remove debris or particles

AIR TUBING

ATTACHMENT PIPE

Discharge Pump Installation

A

B

To prevent the possible air lock, B has to higher than A

(Optional)

AIR VENT HOSE

WATER LEVEL

MUST BE PLACED HIGHER THAN WATER LEVEL