Inactivity Timeout: Determines how long the IPS will wait for

additional commands during periods of inactivity. When the Timeout

Period elapses, the user will be disconnected from the IPS command

mode. (Default = 2 Minutes.)

Command Confirmation: When enabled, the IPS will display a

confirmation prompt before executing certain commands. When

disabled, the prompt will be suppressed and commands will be executed

immediately. (Default = On/Enabled.)

Automated Mode: When enabled, the IPS will execute switching, reboot

and exit commands without displaying a confirmation prompt, status

screen or confirmation messages. For more information, please refer to

Section 6.4. (Default = Off.)

Note:

When this option is enabled, security functions are suppressed,

and users are able to access configuration menus and control plugs

without entering a password. If security is a concern and the

Automated Mode is required, it is recommended to use the IP Security

feature (Section 5.3.4.1) to restrict access.

Manual Switch Button: Enables and configures the Default Button’s

manual plug control function, but does not effect the Default Button’s

ability to reset parameters to default values. (Default = "On".)
Off: Disables the manual plug control function.
On: Enables manual plug control. When Default is pressed and held

for three seconds, all outlets will be toggled On or Off.

Command Prompt: Allows the Text Interface command prompt to be

set to either "IPS", "NPS", or "NBB." (Default = IPS.)

Default Parameters: Resets the IPS to default parameters. All menu

selected parameters, including port names and passwords, will be cleared.

This only is only available via the Text Interface.
Note:

If this function is invoked via the Network Port, the IP address

will not be reset until you break your connection to the Network Port.

If this function is invoked via the Console Port, the IP Address will be

reset immediately.