Western Telematic IPS-800-D20 User Manual

Page 43

Advertising
background image

6-5

Operation

To Switch Plugs, or initiate a Boot Cycle, proceed as follows:

1. Switch Plug(s) On: To power-on a plug, type

/ON n and press [Enter].

Where "

n" is the number or name of the desired plug.

For example:

/ON 1 or /ON ROUTER

2. Switch Plug(s) Off: To power-off a plug, type

/OFF n and press

[Enter]. Where "

n" is the number or name of the desired plug. Note that

the "

/OFF" command can also be entered as "/OF". For example:

/OFF 2 or /OF ROUTER

3. Boot Plug(s): To initiate a Boot cycle, type

/BOOT n and press [Enter].

Where "

n" is a the number or name of the desired plug. Note that the

"

/BOOT" command can also be entered as "/BO". For example:

/BOOT 1 or /BO ATMSWTCH

4. Set Plugs to Power Up Defaults: Type

/D and press [Enter]. Plugs

will be set to their default On/Off status, which is defined using the Plug

Parameters Menu as described in Section 5.3.3.

Notes:

• When you have accessed command mode using the System

Password, the Default command will be applied to all plugs.

• When you have accessed command mode using a Plug (User)

Password, the Default command will only be applied to the plugs

permitted by the password.

5. Suppress Command Confirmation Prompt: To execute a Boot/On/Off

command without displaying the "Sure?" prompt, include the "

,Y" option

at the end of the command line. For example:

/ON ROUTER,Y or /BOOT 2,Y