SCANTEAM 6980 User’s Guide

In Programming mode, the following parameters are

programmable:

communication parameters

beeper enable/disable

MSR track decode selection

Note:

To set options in the “Programming” mode all commands MUST BE
typed in with an AT type keyboard.

Enabling or Disabling Track Configurations and / or Beeper

1.

Turn off power to the SCANTEAM 6980. (If a PC provides
power to the MSR, then turn the PC off.)

2.

Set MSR DIP switch position 8 to OFF.

3.

Turn on power to the MSR.

4.

Run the software utility by typing the executable file name

at the command line. The executable file is that shown on
the SCANTEAM 6980 Programming Utility disk received

with the MSR.
Example: A:\MENU100A.EXE
The disk is in drive A and the executable file name shown on

the disk is MENU100A.EXE."

5.

Follow the setup instructions on the disk:

Select the COM port, baud rate, number of data bits and

parity. Communication parameters selected must match

those set by the switch selections of the MSR being

programmed.

Select the track enable/disable configuration you need.

Enable or disable the beeper.

6.

Turn off power to the MSR.

7.

Set MSR DIP switch position 8 to ON.

8.

Reapply power to the MSR.

Note:

Triple track enable/disable options are not available with a two track
MSR.