background image

FEATURES & OPERATING CONTROLS (continued)

3

ITEM

DESCRIPTION

CANOPY

Removable canopies aid in vapor capture at entry and exit of the conveyor
warmer. Canopies hang from mounting pins at each end of the hood.

ELECTRICAL

The hood plugs into a NEMA 5-15R (120V) or 6-15R (208/240V) receptacle
with a 6' power cord. An illuminated power switch on the front panel is used
to start/stop the hood fan.

EXHAUST

The hood uses an exhaust fan to provide air movement. The fan exhausts
through a screened opening in the top of the hood.
IMPORTANT: DO NOT block exhaust opening.

FILTERS

The hood uses two filters. A high efficiency filter is used to capture
particulate emissions.
A charcoal filter is used to help control odors.
Filters are accessed by opening a hinged panel on the front (operator's)
side of the hood.
Filter operation is monitored by a vacuum switch. When the filter(s)
become loaded to the point of being unable to remove particulates, a front
panel "change filters" indicator will glow.

NAMEPLATE

Provides Manufacturer, Model and Serial Number information.
Also, provides electrical ratings.

TOP PANEL

CAUTION!

Electric Shock Hazard
Exposed Electric Circuits
Top panel must be opened ONLY by qualified personnel.
Allows access to interior components.
DO NOT stack anything on top of the hood.

STD 4

This appliance conforms to NSF Standard 4 for sanitation only if installed
and maintained according to the instructions in this manual.

This appliance is

U

Listed for 120V and 208 - 240V.

This appliance is

V

Listed for 120V and 208 - 240V.


IMPORTANT: For use with conveyor warmer of 9,000 watts maximum.


NOTE: This ductless hood has not been evaluated to the requirements of

NFPA 96.
Local jurisdictions may require additional evaluations for installation
of this product.