3. Place pump assembly inside tank,

keeping fl oat away from the walls of
the tank.

4. Run power cord and switch cord

through holes in the power cord seal.

5. Insert seals into the holes in the lid as

shown in Figure 2.

6. Lubricate discharge pipe and seal

with soapy water.

7. Slide the lid (while holding the

discharge seal in place) over the
discharge pipe.

8. Line up the holes in the lid with the

threads in the tank.

9. Secure lid to tank using the screws

and washers provided. (See Figure 3)
Hand tighten all screws and then fully
tighten with a 7/16 in. wrench. Do
not over-tighten.

Installation

Tools Required for Installation (not
included): PVC Glue, 7/16 in. wrench and
a screwdriver.

1. Connect discharge pipe (See Figure 4)

on Laundry Tray System to an existing
drain. Make sure all connections are
sealed.

2. Insert 1-1/2 in. Schedule 40 PVC pipe

into vent opening on top of Laundry
Tray System (See Figure 4). Insert pipe
2 to 3 inches into vent opening.

3. Connect Intake of this Laundry Tray

System (See Figure 4) to your washing
machine or other source. The threads
are 1-1/2 in. NPT.

2

Operating Instructions and Parts Manual

www.waynepumps.com

Support pump and

piping when

assembling and after installation. Failure
to do so could cause piping to break,
pump to fail, etc. which could result in
property damage and/or personal injury.

4. Protect electrical cord from sharp

objects, hot surfaces, oils, and
chemicals. Avoid kinking the cord and
replace damaged cords immediately.

NOTE: Make sure there is adequate room
for the float switch to move freely for
operation.

This pump is NOT

designed for use in

septic tanks or underground vaults to
handle raw sewage or effl uents. NEVER
use this unit in hazardous or explosive
locations.

Assembly

(continued)

Figure 2: Attach Seals to Tank Lid

Figure 3: Attach Seals to Tank Lid

PVC

Figure 4: Installation

Discharge

Ventilation

GFCI
Outlet

Water
Inlet

Check Valve

Keep fl oat free of

obstruction

Place the system

on a fl at surface