Troubleshooting suggestions – Wells F-88 User Manual

Page 11

Advertising
background image

DESCRIPTION

POSSIBLE PROBLEM

SUGGESTED REMEDY

Fryer will not heat

Not plugged in or circuit breaker
tripped

Plug into proper receptacle
Reset circuit breaker

Fuse blown

Contact Wells Authorized Service
Agency for repairs

Heat switch not ON

Press heat switch ON

Temperature control knob not set to
desired temperature

Set to desired temperature

Hi-limit safety tripped

Clean element

1

, reset hi-limit

Damaged internal component

Contact Wells Authorized Service
Agency for repairs

Fryer will not maintain
temperature

Temperature control thermostat
thermobulb contaminated with
cooking debris

Clean element

2

Damaged internal component

Contact Wells Authorized Service
Agency for repairs

Fryer leaks oil

Damaged frypot

Contact Wells Authorized Service
Agency for repairs

Element head will not
raise

Frypot out of position, or has excess
cooking debris in bottom

Check frypot for position
Clean frypot

Element head will not
stay in the up position

Damaged hinge bracket or support
rod

Contact Wells Authorized Service
Agency for repairs

Element head will not
lower

Damaged hinge bracket or support
rod

Contact Wells Authorized Service
Agency for repairs

Timer not set

Set to desired cook time

Timer "PUSH" button not pushed

Push to start

Damaged internal component

Contact Wells Authorized Service
Agency for repairs

Basket lift will not raise

Damaged internal component

Contact Wells Authorized Service
Agency for repairs

Basket lift will not lower

1

The hi-limit safety is designed to shut down the fryer if the oil temperature exceeds 440ºF. A build-up

of cooking debris between the heating element and the thermobulb of the hi-limit safety will cause the

hi-limit to trip prematurely. Clean the element so that oil may circulate freely between the element

and the thermobulb. Reset the safety by pressing the red button on the bask of the element head.

2

A build-up of cooking debris between the heating element and the thermobulb temperature control

thermostat will cause inconsistent temperatures. Clean the element so that oil may circulate freely

between the element and the thermobulb.

TROUBLESHOOTING SUGGESTIONS

9

M

302 p/n 30

7589

OpM

Counterto

p A

u

toli

ft Frye

rs

Advertising