Indoor installation instructions, Fig. 3, Fig. 2 – White Outdoor FUEL HD120 User Manual

Page 10

Advertising
background image

EYEBOLT

NUT

FLAT WASHER

CAGE NUT

CHAIN

CASE TOP

POWERED EXHAUST FAN

1 FT. CLEARANCE
(BACK OF HEATER TO WALL)

ENTRY/EXIT

SHUTTERED AIR
INLET

CHAIN/CABLE

SEDIMENT TRAP

GAS HOSE

MANUAL SHUTOFF VALVE

SECOND STAGE
REGULATOR
(VENT POINTED DOWN)

GAS SUPPLY LINE

HEATER

(SUPPORTED BY

METAL FRAME

OF GREENHOUSE)

AIR FLO

W

FIG. 3

9

This heater may be mounted within the greenhouse for

indoor heating applications. The heater may be installed on

an optional indoor mounting bracket kit, part number

23651, which is installed on freestanding supports or

mounted directly to the structure’s wall. Separate

installation instructions accompany the kit.

The heater may also be suspended by chain to the

greenhouse’s overhead structure by using an optional chain

hanging kit, part number 08748. Refer to the following

instructions and illustrations.

1. Assemble eyebolts and chain according to the

illustration and tighten all eyebolts securely.

See Fig. 2.

FIG. 2

2. Be sure heater is securely fastened to overhead

supports and is hanging level. (Check crosswise and

lengthwise.)

3. See Fig. 3 for typical indoor installation. In any

installation, consideration must be given to making

sure the heater is located away from the people

entering or exiting the greenhouse so they cannot

accidentally knock the heater or tamper with the

heater and its gas supply line in any way. Additionally,

the heater must be located so that it does not block

the normal entryway or exit of the building. Make

sure you observe and obey minimum clearance

distances to combustible materials as stated in the

specification section of this owner’s manual and on

the heater’s dataplate.

INDOOR INSTALLATION INSTRUCTIONS

Advertising