Air diverter installation instructions – White Outdoor FUEL HD120 User Manual

Page 9

Advertising
background image

-- With the main burner in operation, check all

connections, hose connections, fittings and

joints as well as the gas control valve inlet and

outlet connections with approved gas leak

detectors.

-- If a leak is detected, check the components

involved for cleanliness in the thread areas

and proper application of pipe compound

before further tightening.

-- Tighten the gas connection as necessary to

stop the leak.

-- If necessary, replace the parts or components

involved if the leak cannot be stopped.

-- Ensure all gas leaks have been identified and

repaired before proceeding.

11. A qualified service agency must check for proper

operating gas pressure upon installation of the

heater.

12. Light according to instructions on heater or within

owner's manual.

13. It is extremely important to use the proper size and

type of gas supply line to assure proper functioning of

the heater. Contact your fuel gas supplier for proper

line sizing and installation.

14. This heater can be configured for use with either L.P.

gas vapor withdrawal or natural gas. Consult the

dataplate for the gas configuration of the specific

heater. Do not use the heater in an L.P. gas liquid

withdrawal system or application. If you are in doubt,

contact the L.B. White Co., Inc.

15. Eventually, like all electrical/mechanical devices, the

thermostat can fail. Thermostat failure may result in

either an underheating or overheating condition which

may damage or kill plants. Plants should be protected

by a separate back-up control system that limits high

and low temperatures and also activates appropriate

alarms.

16. Take time to understand how to operate and maintain

the heater by using this Owner’s Manual. Make sure

you know how to shut off the gas supply to the

building and also to the individual heater. Contact

your fuel gas supplier if you have any questions.

17. Any defects found in performing any of the service or

maintenance procedures must be eliminated and

defective parts replaced immediately. The heater

must be retested by properly qualified service

personnel before placing the heater back into use.

18. Do not exceed input rating stamped on the dataplate

of the heater. Do not exceed the burner manifold

pressure stated on the dataplate. Do not use an

orifice size different than specified for the specific

input rating of this heater, fuel type configuration and

altitude.

1. Optional air diverters can be installed in the heater

outlet to provide direction to the heated air as it exits

the heater. Installation options include installing the

diverters in such a way as to broadly distribute the air

in two 45 degree paths or to focus the air flow in one

45 degree direction. See Fig. 1.

2. The air diverters may require hand forming prior to

installation. Make 90 degree bends utilizing the

performations provided. Diverter should then have

the shape shown in Fig. 1.

3. The air diverter’s tabs on each half will pop into the

blower outlet between the inside of the case

assembly and the blower housing outlet. If the

notched tabs do not pop into the blower outlet, loosen

(do not remove) the blower outlet screws. Doing this

provides a gap into which you can insert the tabs.

Retighten the screws after installation.

FIG. 1

(Typical installation allowing two directions of air movement.)

(Optional accessory on some models.)

(Appearance of the outlet on heater may vary from model to model.)

AIR DIVERTER

INSTALLATION INSTRUCTIONS

Alternate Air Diverter Installations

TABS

DIVERTER
HALVES

OUTLET
SCREWS

FORMED
OUTLET GUARD

NOTCHES IN MOUNTING TABS

8