Maintenance and troubleshooting – Weslo WLEVEX12920 User Manual

Page 11

Advertising
background image

11

Inspect and tighten all parts of the exercise cycle reg-
ularly. Replace any worn parts immediately.

To clean the exercise cycle, use a damp cloth and a
small amount of mild detergent. Important: To avoid
damage to the console, keep liquids away from
the console and keep the console out of direct
sunlight.

BATTERY REPLACEMENT

If the console display becomes dim, the batteries
should be replaced; most console problems are the
result of low batteries. To replace the batteries, refer
to step 5 on page 6 and remove the console from the
handlebar. Next, refer to step 4 on page 5 and insert
three batteries into the console. Reattach the console
to the handlebar, being careful not to pinch the wires.

HOW TO ADJUST THE REED SWITCH

If the console does not display correct feedback, the
reed switch should be adjusted. In order to adjust the
reed switch, the left side shield must be removed.

Turn the Crank (21) to the position shown. Using an
adjustable spanner, turn the Left Pedal (24) clockwise
and remove it. Next, remove the five M4 x 25mm
Screws (52) and the M4 x 19mm Screw (54) from the
Left Side Shield (17). Carefully remove the Left Side
Shield.

Next, locate the Reed Switch (43). Turn the Crank
(21) until the Magnet (38) is aligned with the Reed
Switch. Loosen, but do not remove, the M4 x 12mm
Screw (46). Slide the Reed Switch slightly closer to or
away from the Magnet. Retighten the Screw. Turn the
Crank for a moment. Repeat until the console dis-
plays correct feedback. When the Reed Switch is cor-
rectly adjusted, reattach the left side shield and the
left pedal.

PULSE SENSOR TROUBLESHOOTING

Refer to step 3 on page 10.

MAINTENANCE AND TROUBLESHOOTING

52

54

17

21

38

43

46

52

24

21

Advertising