Warning, Cc aa ee cc ee, Installation to solid concrete or cinder block 1 – Westinghouse MT80 THIN User Manual

Page 6

Advertising
background image

6 of 8

ISSUED: 03-02-05 SHEET #: 201-9323-1

Visit the Westinghouse Web Site at www.westinghousedigital.com

For customer service call

1-866-287-5555

.

Installation to Solid Concrete or Cinder Block

1

Use wall plate (AA), making sure that it is level, as
a template to mark holes. Drill four 1/4" (6 mm) dia.
holes to a minimum depth of 2-1/2" (64 mm). Insert
anchors (EE) in holes flush with wall as shown
(right). Place wall plate over anchors and secure
with #14 x 2.5" screws (CC). Tighten all fasteners.

• When installing Westinghouse wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual con-

crete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a
solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware

and components.

WARNING

CUT

A

W

A

Y

VIEW

INCORRECT

concrete
surface

1

3

2

EE

Drill holes and insert anchors (EE).

CORRECT

Place plate (AA)

over anchors (EE) and secure with

screws (CC).

Tighten all fasteners.

wall

plate

plaster/

dry wall

concrete

wall plate

concrete

plaster/

dry wall

• Always attach concrete expansion anchors directly to

load-bearing concrete.

• Never attach concrete expansion anchors to con-

crete covered with plaster, drywall, or other finishing
material. If mounting to concrete surfaces covered
with a finishing surface is unavoidable, the finishing
surface must be counterbored as shown below. If
plaster/drywall is thicker than 5/8", custom fasteners
must be supplied by installer.

WARNING

AA

• Tighten screws so that wall plate is firmly attached,

but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

WARNING

CC

AA

EE

CC

EE

solid concrete

cinder block