2 installing the ocu-dp 5 card, 2 ocu-dp 2 card description (8249), 1 card jumpers/switch settings – Zhone Technologies 900 User Manual

Page 90: 2 installing the ocu-dp 2 card, 3 ocu-dp 10 card description (824660), 2 installing the card, Ocu-dp 10 card description (824660) -2

Advertising
background image

3-2

IMACS System Release 5.1.6

Data Cards

Model No.

Running Head

OCU-DP Card Descriptions

OCU-DP Card

3.2.1.2

Installing the OCU-DP 5 Card

Install the OCU-DP 5 Card in any user card slot. These slots are U1 to U8 on the two-sided
chassis and front-loading chassis with power supplies on top, and P1 to P4 or W1 to W4 on
the front-loading chassis with power supplies on the side.

3.2.2

OCU-DP 2 Card Description (8249)

The OCU-DP 2 Card has only two ports. Each card may be connected to a DSU/CSU
operating at one of the rates stated above for the OCU-DP 5 Card. In addition, the OCU-DP 2
supports BCH error correction, performance monitoring, and the CSU operating mode.

3.2.2.1

Card Jumpers/Switch Settings

The OCU-DP 2 Card does not have any jumpers or switches on its mainboard.

3.2.2.2

Installing the OCU-DP 2 Card

Install the OCU-DP 2 Card in any user card slot. These slots are U1 to U8 on the two-sided
chassis and front-loading chassis with power supplies on top, and P1 to P4 or W1 to W4 on
the front-loading chassis with power supplies on the side.

3.2.3

OCU-DP 10 Card Description (824660)

The OCU-DP 10 Card supports up to ten data ports operating at speeds up to 64 kbps
inclusive. This card interfaces directly with DSU/CSUs which can be located up to 4 miles
away.

3.2.3.1

Card Jumpers/Switch Settings

The OCU-DP 10 Card does not have any jumpers or switches on its mainboard.

3.2.3.2

Installing the Card

Install the OCU-DP 10 Card in any user card slot. These slots are U1 to U8 on the two-sided
chassis and front-loading chassis with power supplies on top, and P1 to P4 or W1 to W4 on
the front-loading chassis with power supplies on the side.

Advertising