Mounting the xadc and panel when connected – Xantrex Technology Xantrex AC to DC Converter XADC User Manual

Page 23

Advertising
background image

Installation Instructions

975-0301-01-01

23

AC Loads

To install the AC loads:

1. Route the AC load cables through the knockouts in the back of the panel.

2. Install breaker(s) for your AC loads. See the documentation for your breaker

to determine how it installs.

3. Connect the hot lead (black) from each AC load to a breaker.

4. Connect the neutral lead (white) from each AC load to the rear AC bus on the

panel, marked “AC Neutral Terminal”.

5. Connect the ground lead (green or bare) from each AC load to the front AC

bus on the panel, marked “Equipment Grounding Terminal”.

Mounting the XADC and Panel when Connected

To mount the XADC and panel when connected:

1. Slide the complete unit into the mounting cutout.

2. Fasten the complete unit into the cutout and secure using 6 × #6 or #8 pan

head, round head or washer head screws suitable for mounting the unit onto
particleboard or wood.

3. Install the XADC faceplate and tighten the four screws (do not overtighten as

this may cause stripping of the screw threads).

4. Install the DC fuse cover.

5. Install the panel faceplate and tighten the center screw (do not overtighten as

this may cause stripping of the screw threads).

6. Close the hinged door.

Important:

Make a note of which AC load has been connected to which breaker using

the provided label on the panel to the side of the breakers. Use pencil in case the circuit is
changed in the future.

Figure 17 XADC AC Connections

AC input knockouts

Main AC input and AC
loads neutral connection
to AC Neutral Terminal

Main AC input and AC loads
ground connection to
Equipment Grounding
Terminal

AC loads “hot” to
any breaker except
reserved AC line
breaker

AC line connection
to breaker 1 (30A
panel) or breaker
4+5 (50A panel)

Advertising