Installation electrical connection – Zanussi BMS 641 - BST 6 User Manual

Page 20

Advertising
background image

20

The oven is designed to be connected to 230-240V (50Hz)

electricity supply.

The oven has an easily accessible terminal block which

is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

-

Earth terminal

THIS OVEN MUST BE EARTHED

Model BMS 641 is provided with a a type H05RR-F

connection cable with section 3x1,5 mm

2

.

Model BST 6 is supplied without connection cable. A

suitable one must be fitted to the appliance, according to

the following type list:

— H07 RN-F

— H05 RN-F

— H07 RR-F

— H05 VV-F

It is necessary that you install a double pole switch

between the oven and the electricity supply (mains), with

a minimum gap of 3mm between the switch contacts and

of a type suitable for the required load in compliance with

the current rules.

The switch must not break the yellow and green earth

cable at any point.

Important

After installation and connecting, the cable must be

placed so that it cannot at any point reach a temperature

of more than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse

and the domestic installation can support the load; and

that the power supply is properly earthed.

The manufacturer disclaims any

responsibility should these safety

measures not be carried out.

DIMENSIONS

Height

580 mm.

OF RECESS

Width

560-570 mm.

Depth

550 mm.

DIMENSIONS

Height

320 mm.

OF THE

Width

420 mm.

OVEN CAVITY

Depth

390 mm.

Oven capacity 53.2 litres

Heating elements rating (230 V)
Oven element

1.8 kW

Top element

0.8 kW

Bottom element

1.0 kW

Convection element

2.0 kW

Grill element

1.75 kW

Double Grill element

2.55 kW

Convection Fan

30 W

Oven Light

25 W

Cooling Fan

25 W

Total Rating (230-240 V)

2.6 kW

This oven must be installed by qualified

personnel to the relevant British Standards.

Technical Data

The oven must be installed according to

the instructions supplied.

Installation

Electrical Connection

Advertising