Table 6: bq heating capacities – York BQ 036 User Manual

Page 19

Advertising
background image

036-21508-005-A-0305

Unitary Products Group

19

TABLE 6: BQ HEATING CAPACITIES

CAP

& KW

-10

0

10

20

30

40

50

60

MBH

13.1

16.4

23.5

29.1

30.2

41.7

47

48.2

KW

2.9

3

3.2

3.3

3.5

3.7

3.8

3.9

MBH

11.9

15

21.5

26.7

27.7

38.2

43.1

44.1

KW

3

3.1

3.4

3.4

3.6

3.8

3.9

4.1

MBH

10.9

13.6

19.6

24.3

25.2

34.8

39.3

40.2

KW

3.1

3.2

3.4

3.5

3.8

3.9

4.1

4.2

MBH

12.4

15.5

22.5

27.7

28.7

39.6

44.7

45.8

KW

2.7

2.9

3

3.1

3.3

3.5

3.6

3.7

MBH

11.4

14.1

20.3

25.2

26.1

36.1

40.7

41.6

KW

2.9

3

3.2

3.3

3.5

3.7

3.8

3.9

MBH

10.4

13.1

18

23.2

24.2

33.3

37.6

38.5

KW

3

3.1

3.2

3.4

3.6

3.8

3.9

4

MBH

11.8

14.8

21.3

26.5

27.5

37.8

42.7

43.7

KW

2.7

2.8

3

3.1

3.3

3.4

3.5

3.6

MBH

10.8

13.5

19.4

24

24.9

34.4

38.8

39.7

KW

2.9

3

3.1

3.3

3.4

3.6

3.7

3.8

MBH

9.9

12.4

17.8

22

22.9

31.5

35.6

36.5

KW

2.9

3.1

3.2

3.4

3.5

3.7

3.8

3.9

MBH

11.2

14.1

20.3

25.2

26.1

35.9

40.6

41.6

KW

2.6

2.7

2.9

3

3.3

3.3

3.5

3.5

MBH

10.2

12.8

18.5

22.8

23.6

32.7

36.9

37.8

KW

2.8

2.9

3

3.2

3.3

3.5

3.6

3.7

MBH

9.3

11.7

16.7

20.7

21.5

29.8

33.6

34.4

KW

2.8

3

3.1

3.3

3.4

3.6

3.7

3.8

MBH

12.3

17.3

22.5

28.2

36.3

44.5

53.8

61.6

KW

3.4

3.5

3.6

3.6

3.8

4

4.6

5.2

MBH

11.8

16.6

21.6

27.1

34.9

42.8

51.7

59.2

KW

3.5

3.6

3.8

3.8

4

4.2

4.8

5.4

MBH

10.9

15.3

19.9

24.9

32.1

39.4

47.6

54.5

KW

3.6

3.7

4

4

4.1

4.4

5

5.7

MBH

12.1

17

22

27.7

34.5

42.3

51.2

58.6

KW

3.3

3.4

3.5

3.6

3.6

3.8

4.4

5

MBH

11.6

16.3

21.2

26.6

33.2

40.7

49.2

56.3

KW

3.4

3.5

3.6

3.7

3.8

4

4.6

5.2

MBH

10.7

15

19.5

24.5

30.5

37.4

45.3

51.8

KW

3.5

3.6

3.8

3.9

4

4.2

4.8

5.4

MBH

10.9

15.3

19.9

24.9

31.7

38.9

47

53.8

KW

3.1

3.2

3.3

3.4

3.5

3.7

4.2

4.8

MBH

10.5

14.7

19.1

24

30.5

37.4

45.2

51.7

KW

3.2

3.3

3.4

3.5

3.6

3.8

4.4

5

MBH

9.6

13.5

17.6

22

28.1

34.4

41.6

47.6

KW

3.3

3.4

3.5

3.6

3.8

4

4.6

5.2

MBH

18.2

24.7

31.1

38.4

45.6

55.4

64.7

75.6

KW

5

5.1

5.2

5.3

5.3

5.6

5.9

6.5

MBH

17.5

23.7

29.9

37

43.9

53.3

62.2

72.7

KW

5.2

5.3

5.4

5.5

5.6

5.9

6.2

6.8

MBH

16.1

21.8

27.5

34

40.4

49

57.2

66.9

KW

5.4

5.6

5.7

5.8

5.9

6

6.5

7.2

MBH

18

24.4

30.8

38.1

45

54.7

63.9

74.7

KW

4.7

4.8

4.9

5

5.3

5.5

5.8

6.4

MBH

17.3

23.5

29.6

36.6

43.3

52.6

61.4

71.8

KW

4.9

5

5.1

5.2

5.5

5.8

6.1

6.7

MBH

15.9

21.6

27.2

33.7

39.8

48.4

56.5

66.1

KW

5.1

5.3

5.4

5.5

5.8

6.1

6.4

7

MBH

16.2

22

27.8

34.3

41.4

50.2

58.7

68.6

KW

4.5

4.6

4.7

4.8

5

5.3

5.5

6.1

MBH

15.6

21.2

26.7

33

39.8

48.3

56.4

66

KW

4.7

4.8

4.9

5

5.2

5.5

5.8

6.4

MBH

14.4

19.5

24.6

30.4

36.6

44.5

51.9

60.7

KW

4.9

5

5.1

5.2

5.5

5.8

6.1

6.7

1750

1400

55

70

80

55

70

80

55

70

80

55

70

80

55

70

80

70

55

80

70

80

55

70

80

55

70

80

55

70

80

1500

4

2000

2500

1200

1600

OUTDOOR AIR TEMPERATURE, °F (72% RH)

55

5

CFM

RET. AIR °F

Model Tonnage

2000

1050

1200

3

Advertising
This manual is related to the following products: