Maintenance intervals, Preventive maintenance intervals, Maintenance intervals -2 – Xerox 701P44148 User Manual

Page 182: Preventive maintenance intervals -2

Advertising
background image

DocuColor 8000/7000 O perator Manual

11-2

11. Maintenance

Maintenance intervals

The scanner requires minimal maintenance by the operator.
However, it is essential that you perform these tasks when
indicated to ensure reliable operation and maximum product life.

Preventive maintenance intervals

To avoid any maintenance delays, ensure that you have the
necessary spare parts and cleaning supplies on hand.

Component

Action

Maintenance interval

Air Filter

Replace

Replace after 3,000 hours.

The scanner software will notify you when
the Air Filter requires replacement.

Refer to the online Help (Advanced
Scanning) for step-by-step
instructions on replacing the filter.

Feed and Retard
Rollers

Replace

Replace after 100,000 feeds.

The scanner software will notify you when
the Feed and Retard Rollers require
replacement.

Refer to the online Help (Advanced
Scanning) for step-by-step
instructions on replacing the rollers.

Automatic
Document
Feeder

Clean

Clean the ADF whenever there is paper dust
visible in the feeder.

Refer to the online Help (Advanced
Scanning) for step-by-step
instructions on cleaning the ADF.

Document Glass

Clean

Clean daily or whenever specks are
noticeable in scanned images.

Refer to the online Help (Advanced
Scanning) for step-by-step
instructions on cleaning the

Document Glass.

Constant Velocity
Transport (CVT)
Ski

Clean

Clean whenever hole-punch marks are
noticeable in scanned images.

Refer to the online Help (Advanced
Scanning) for step-by-step
instructions on cleaning the CVT Ski.

Advertising