CHAMPIONÆ PLUS

SINGLE PACKAGE

HEAT PUMPS

B1HP024 THRU 048

2 THRU 4 NOMINAL TONS

13 SEER

FACTORY MOUNTED TXV

DESCRIPTION

These packaged heat pumps are designed for outdoor

installation. Only utility and duct connections are required

at the point of installation.
Field-installed electric heater accessories are available to

provide electric heat, if required.

STANDARD FEATURES / BENEFITS

OPERATING EFFICIENCY
All units provide high operating efficiencies of 13 SEER, 3.3

COP or greater, and 7.6 HSPF. All efficiencies exceed leg-

islated minimum levels.
ON SITE FLEXIBILITY
All model sizes share a common, compact design cabinet

with a single footprint. The installer has the flexibility of set-

ting one curb or pad and placing the proper tonnage unit

after the internal load has been determined. Field convert-

ible duct connections, from side shot to down shot, allows

the installer greater flexibility and the need to carry less

inventory.
LOWER INSTALLATION COST
Installation time and costs are reduced by easy power and

control wiring connections. The small base dimension

means less space is required on the ground or roof. Plus,

the installer can fit this unit between the wheel wells of full

size pick-up truck. All models are under 500 pounds.

All units are completely wired, charged with R-22 and

tested prior to shipment. Unique test stations, are used to

insure product quality. Refrigerant charge, and component

part numbers are verified via computers at manufacturing

point. Vital run test statistics, such as, system pressure,

motor currents, air velocity and temperature unit vibration
are monitored and recorded by the system to insure unit

performance.
Equal size, side supply and return duct connections allow

easy hook-up of ducts to match low crawl spaces without

transition pieces.
UTILITY CONNECTIONS MADE EASY
Electrical utility knockouts are provided through the bottom,

as well as the side of the unit. Utility connections can be

made quickly and with a minimum amount of field labor. A

field supplied and field installed electrical disconnect

switch must be installed.

CONVERTIBLE AIRFLOW DESIGN

The bottom duct openings are covered when they leave the

factory. They are ready for a side supply / side return appli-

cation. If a bottom supply / bottom return application is

desired, you simply remove the two panels from the bottom

of the unit and place them in the side supply / side return

duct openings. No panel cutting is required and no acces-

sory panel is necessary. Convertible airflow design allows

maximum field flexibility and minimum inventory.