Section B

Rinse Solution Tank
Using the clean water rinse tank system (optional on 665),
rinsing the solution tank with clean water is accomplished
via the following steps:

1. Close all valves.
2. Open the clean water rinse tank valve.
3. Open the rinse ball valve.
4. Power ON the liquid pump of the sprayer.
5. Run for 15-30 seconds to thoroughly rinse the

insides of the solution tank. Repeat if needed.

6. Power OFF the liquid pump of the trailer sprayer.

7. Close the clean water rinse tank valve.
8. Close the rinse ball valve.

Only you, the operator can determine the length of time
required to completely rinse all chemical residue from
the sprayer tanks and plumbing systems.

IMPORTANT

IMPORTANT

Turn off a hydraulically driven centrifugal pump using the “float” posi-
tion of the tractor’s hydraulic valve. This allows the motor to stop
slowly helping to protect the motor and motor seals.

Agitation Valve

Rinse Ball Valve

Clean Water

Rinse Tank Valve