Instructions for the installer, Something not working, Engineers technical data – Zanussi GAS HOB ZGG 659 User Manual

Page 7: Overall dimensions, Cut out dimensions, Supply connections, Symptom, Solution

Advertising
background image

7

OVERALL DIMENSIONS

Width:

580 mm

Depth:

510 mm

Height:

88 mm

Weight:

12,5 Kg

Instructions for the Installer

CUT OUT DIMENSIONS

Width:

550 mm

Depth:

470 mm

Thickness: 30 mm

Supply Connections

Gas:
RC 1/2 inch (1/2 inch male) Rear right hand
corner

Electric:
230-V 50Hz supply, 3 core flexible cable with
non rewireable plug.

Appliance Gas supply: LPG 30 mbar

Appliance Class: 3

Appliance category: I 3

Engineers technical data

Burner

Nominal Power LPG (Butane "A") Diameter

Feeding

Tap. By-Pass Pressure

kW

kCal/h

Nozzle

gh

mbar (*)

Auxiliary (dia. 42 mm.)

0,95

814

50

75

28

Semi-rapid (dia. 57 mm.)

1,60

1368

65

126

35

30

Rapid (dia. 90 mm.)

2,45

2095

80

193

45

(*) 1 mbar = 10 mm. water coloumn.

Something Not Working?

If the appliance is not working correctly, please carry out the following checks before contacting your local
Service Centre.

SYMPTOM

„

There is no spark when lighting the gas

„

The gas ring burns unevenly

SOLUTION

‹

Check that the unit is plugged in and the

electrical supply is switched on

‹

Check that the RCCB has not tripped (if

fitted)

‹

Check the burner cap and crown have been

replaced correctly, e.g. after cleaning.

‹

Check the main jet is not blocked and the

burner crown is clear of food particles.

‹

Check the burner cap and crown have been

replaced correctly, e.g. after cleaning.

If after all these checks, your appliance still does not operate correctly, contact your local Service Centre.

Advertising