roubleshooting

17

TROUBLESHOOTING PROCEDURES FOR NAPOLI ISLAND

Issue

Cause

What to do

After installation,
the unit doesn’t
work.

1. The power source is not turned ON.

1. Make sure the circuit breaker and the unit’s

power is ON.

2. The power line and the cable locking connector

is not connecting properly.

2. Check the power connection with the unit is

connected properly.

3. The switch board and control board wirings are

disconnected.

3. Make sure the wirings between the switch

board and control board are connected
properly.

4. The switch board or control board is defective.

4. Change the switch board or control board.

Light works,
but motor is not
turning.

1. The motor is defective, possibly seized.

1. Change the motor.

2. The thermally protected system detects if the

motor is too hot to operate and shuts the motor
down.

2. The motor will function properly after the

thermally protected system cool down.

3. Damaged capacitor.

3. Change the capacitor.

4. The switch board or control board is defective.

4. Change defective part.

The unit is
vibrating.

1. The motor is not secure in place.

1. Tighten the motor in place.

2. Damaged blower wheel.

2. Replace the blower.

3. The hood is not secured in place.

3. Check the installation of the hood.

4. The switch board or control board is defective.

4. Change defective part.

The motor is
working, but the
lights are not.

1. Defective halogen bulb.

1. Change the halogen bulb.

2. The light bulb is loose.

2. Tighten the light bulb.

The hood is
not venting out
properly.

1. The hood might be hanging to high from the

cook top.

1. Adjust the distance between the cook top and

the bottom of the hood within 28” and 36”
range.

2. The wind from the opened windows or opened

doors in the surrounding area are affecting the
ventilation of the hood.

2. Close all the windows and doors to eliminate

the outside wind fl ow.

3. Blockage in the duct opening or ductwork.

3. Remove all the blocking from the duct work or

duct opening.

4. The direction of duct opening is against the wind.

4. Adjust the duct opening direction.

5. Using the wrong size of ducting.

5. Change the ducting to at least 6” or higher

for the internal blower and 8” or higher for the
external blower.

Metal Filter is
vibrating.

1. Metal

fi lter is loose.

1. Change the metal fi lter.