INSTALLATION INSTRUCTIONS

2. REMOVAL OF THE DOOR

2.1 To remove the door:

Using a 5mm A/F Hey Key remove the door by opening,

removing the 4 bolts and lifting the door free of the

appliance body.

PR7084

4 Bolts

3. REMOVAL OF THE LOG GUARD

3.1 To remove the log guard:

Lift log guard clear of the supporting brackets.

Rotate to clear the sides of the door opening.

Do not use appliance without the log guard in position.

4. REMOVAL OF THE BAFFLE

4.1 The appliance is fitted with a baffle in the top of the firebox

to maintain efficient combustion.

4.2 Allow the appliance to cool fully before removing baffle

system.

PR9040

Baffle

5

4.3 Remove the log guard from the appliance to give access to

the firebox.

1.5 Reposition clamps by hand through the flue opening and

tighten using a 13A/F spanner. Check the clamps are

against the throat forming lintel as shown in Diagram 3.

PR9039

3

Reach through door

and up and out

of flue opening to

adjust clamps

Throat

forming lintel

Clamp

Milner

brick

ø 16mm

Rope seal

1.6 Check the ø16mm rope seal is still in the correct position.

The appliance must be sealed against the face of the

chimney breast / fire surround and at the hearth to the base

of the appliance. This seal must be made air-tight with the

use of heat resistant sealant such as fire cement or very

high temperature flexible sealer.

1.7 Drill 2 appropriately placed ø10mm holes in the Milner

hearth. Secure the stove to the hearth via the holes shown

in Diagram 4 using metal wall plugs and bolts.

PR9034

4

Attach stove to

hearth via holes

in floor of stove

1.8 Refit all internal components.