Zebra Technologies A300 User Manual

Page 32

Advertising
background image

Zebra )300 User’s Guide

!

Media requirements

Zebra recommends use of Zebra brand media. All media
must be direct thermal media. Media may be continuous,
die-cut, or notched. Notched media must have a notch
which is 1/4

² wide ´ 3/32² long located on the left side

of the label as it feeds through the printer.

Physical size (L

´ W ´ H)

9.7

² ´ 7.0² ´ 6.0²

249 mm

´ 179 mm ´

154 mm

Weight (without media)

3.35 lb

1.52 kg

Temperature
range

Operating

50° to 104° F

10° to 40° C

Storage

-4° to 140° F

-20° to 60° C

Relative humidity, operation and
storage

10 to 90% R.H.

Electrical

External 120 or 230 VAC power supply, depending on
which model you ordered. Additional custom line cords
may also be available.

Communications

36-pin Centronics

®

-compatible parallel port and RS-232

serial port; contact your distributor for information about
ZebraNet™—ethernet connectivity for the A300.

Agency approvals

• UL 544 Medical Equipment Standard Part 42.5
• CSA 22.2 No. 950 Canadian Safety Standard
• Carries the CE mark of compliance.
• IEC 950/EN 60950 International Safety Standard
• FCC Part 15 Subpart B level A Electromagnetic Radia-

tion Standard

• AAME 4.3.2 Medical Standard
• UL 1950 Domestic Safety Standard
• SOR/88-475 Canadian Electromagnetic Radiation

Standard

• EN50082-1 International Immunity Standard
• C.I.S.P.R.-22 Class B European Electromagnetic Radia-

tion Standard

Processor/memory

32-bit microcontroller, 512 kB DRAM

Power line cord

• The overall length must be less than 12.5 ft (3.8 meters)
• It must be rated for at least 3 A, 250 V.
• The chassis ground (earth) MUST be connected to

assure safety and reduce electromagnetic interference.
The ground connection is handled by the third wire
(earth) in the power line cord. See Figure 7.

The AC power plug and IEC 320 connector must bear
the certification mark of at least one international safety
organization (some examples are shown in Figure 2.)

Parallel data cable

For maximum reliability, use a parallel data cable no
longer than 6 ft (1.8 m).

Table 5: Specifications (Continued)

55530lr4 Page 23 Wednesday, March 26, 1997 11:18 AM