Midi data format, Clp-970 – Yamaha CLP-970M EN User Manual

Page 25

Advertising
background image

CLP-970

25

MIDI Data Format

The following RPN messages can be received.

*1 Refer to 1.2.4
*2 '--' indicates that the setting value is ignored.

1.2.23 Assignable controller

By assigning a control change number of 0...95 to a part, the specified effect can be con-
trolled.
This device allows two control change numbers (AC1 and AC2) to be specified for each
part.
The following parameters specify the effect of AC1 and AC2.

• Multi Part Parameter

1. AC1, AC2 PITCH CONTROL
2. AC1, AC2 FILTER CONTROL
3. AC1, AC2 AMPLITUDE CONTROL
4. AC1, AC2 LFO PMOD DEPTH
5. AC1, AC2 LFO FMOD DEPTH
6. AC1, AC2 LFO AMOD DEPTH

• Effect1 Parameter

7. AC1, AC2 VARIATION CONTROL DEPTH

(Valid if Variation Effect is assigned to a part as Insertion)

The AC1 control change number is specified by the Multi Part parameter AC1 CONTROL-
LER NUMBER, and the AC2 control change number is specified by the Multi Part param-
eter AC2 CONTROLLER NUMBER.

1.3 Channel mode messages

These messages specify the basic operation of a part.

1.3.1 All Sound Off

This message silences all currently-sounding notes on the corresponding channel.
However, the settings of channel messages such as Hold 1 and Sostenuto will be main-
tained.

Control#

Parameter

Data Range

120

All Sound Off

0

1.3.2 Reset All Controllers

This message resets the following controllers to their default values.

The following data is not changed
Parameter values specified by program change, bank select MSB/LSB, volume, pan, effect
send levels 1, 3, 4, RPN and NRPN.

Control#

Parameter

Data Range

121

Reset All Controllers

0

1.3.3 All Note Off

This message turns off all notes which are currently on for the corresponding part.
However, if Hold 1 or Sostenuto are on, notes will continue to sound until these are turned
off.

Control#

Parameter

Data Range

123

All Note Off

0

1.3.4 Omni Off

Perform the same processing as when All Note Off is received.

Control#

Parameter

Data Range

124

Omni Off

0

1.3.5 Omni On

Perform the same processing as when All Note Off is received.

Control#

Parameter

Data Range

125

Omni On

0

1.3.6 Mono

Perform the same processing as when All Sound Off is received, and if the value (mono
number) is in the range of 0...16, set the corresponding channel to Mode4* (m = 1).

Control#

Parameter

Data Range

126

Mono

0...16

* Mode4 is a state in which only channel messages on the specified channel will be

received, and notes will be sounded individually (monophonically).

1.3.7 Poly

Perform the same processing as when All Sound Off is received, and set the corresponding
channel to Mode3*.

Control#

Parameter

Data Range

127

Poly

0

* Mode3 is when channel messages will be received only on the specified channel,

and will be sounded polyphonically.

1.4 Program change

This message reports sound selection changes and changes the program number of the
receiving channel.
In order to include changes to the voice bank, Program Change and Bank Select messages
must be sent as a set (see 1.2.1).
When RevPROGRAM CHANGE=OFF for Multi Part Parameter, the program change for
that part is not received.

1.5 Pitch bend

This message conveys movements of the pitch bender.
This message is generally used to modify the pitch of a part, but the depth of the following
seven effects can be controlled.
The effect of this message can be modified by the following parameters.

• Multi Part Parameter

1. BEND PITCH CONTROL
2. BEND FILTER CONTROL
3. BEND AMPLITUDE CONTROL
4. BEND LFO PMOD DEPTH
5. BEND LFO FMOD DEPTH
6. BEND LFO AMOD DEPTH

• Effect1 Parameter

7. BEND VARIATION CONTROL DEPTH

(Valid when Variation Effect is assigned to a part as Insertion)

By default, the Pitch Control effect is applied.
If the Multi Part parameter Rcv PITCH BEND CHANGE = OFF, that part will not receive
pitch bend messages.

1.6 Channel aftertouch

This message conveys the pressure which is applied to the keyboard after playing a note in
order to create tonal changes (for an entire MIDI channel). The pressure can be controlled
for each part. This message will affect the currently-sounding notes.
The effect of this message will be determined by the settings of the following parameters.

• Multi Part Parameter

1. CAT PITCH CONTROL
2. CAT FILTER CONTROL
3. CAT AMPLITUDE CONTROL
4. CAT LFO PMOD DEPTH
5. CAT LFO FMOD DEPTH
6. CAT LFO AMOD DEPTH

• Effect1 Parameter

7. CAT VARIATION CONTROL DEPTH

(Valid when the Variation Effect is assigned to a part as Insertion)

By default, there will be no effect.
If the Multi Part parameter Rcv CHANNEL AFTER TOUCH = OFF, that part will not
receive Channel Aftertouch.

RPN
MSB LSB

Data Entry *1

MSB LSB

Parameter name and value range

00

00

mm -- *2

Pitch bend sensitivity

mm: 00-24 (0...+24 semitones)
Specify up to 2 octaves in semitone steps

00

01 mm ll

Fine

tuning

mm

ll:0000-100 cents

: :

mm

ll:64000 cents

: :

mm

ll:127127+100 cents

[Note]mm ll: 00

127 (=-87.5) cents is

followed by 01 00 (=-87.4) cents.

00

02 mm --

Coarse

tuning

mm: 40 - 64 - 88 (-24...0...+24 semitones)

127 127

--

--

RPN Null

This sets RPN and NRPN numbers to an unset

state. Internal data is not affected.

Controller

Value

Pitch bend change

±0 (center)

Channel pressure

0 (off)

Polyphonic key pressure

0 (off)

Modulation

0 (off)

Expression

127 (maximum)

Hold

0 (off)

Portamento

0 (off)

Sostenuto

0 (off)

Soft pedal

0 (off)

Portamento control

Reset the portamento source note number that was received

RPN

Number unset, internal data is not affected.

NRPN

Number unset, internal data is not affected.

Advertising