Command Sets 4-19

4.6 S-Register

Descriptions

In most bit-mapped S-registers, the default bit value is 0. Non-0 default values are followed by an
asterisk. In some cases, default values are shown in the reference column preceded by +. Some bits are
reserved for factory use and should not be changed.

S-Register default values may vary depending on the country.

Table 4-15 Basic S-Registers "ATSn=x"

COMMAND

FUNCTION & DESCRIPTION

+REF.

S0=

Sets the number of rings on which the modem will answer. 0 value disables
auto-answer.

+000

S1=

Counts and stores number of rings from an incoming call.

+000

S2=

Defines escape code character, default ‘+’ (43 dec.). A value of 128-255
disables the escape code.

+043

S3=

Defines ASCII Carriage Return.

+013

S4=

Defines ASCII Line Feed.

+010

S5=

Defines ASCII Backspace. A value of 128-255 disables the Backspace key’s
delete function.

+008

S6=

Sets the number of seconds the modem waits before dialing if ‘X0’ or ‘X1’ is
selected. If a setting of ‘X2,’ ‘X7’ is selected, the modem will dial as soon as it
detects a dial tone. This register also sets the time-out interval for the “W” dial
modifier to wait for the dial tone. (See also S41b4)

+003

S7=

Sets duration, in number of seconds modem waits for a carrier.

+060

S8=

Sets duration, in seconds, for pause (,) option in Dial command and pause
between command re-executions for Repeat (>) command.

+002

S9=

Sets duration, in tenths of a second of remote carrier signal before recognition.
(Ignored if in non-FSK or half-duplex operation)

+006

S10=

Sets duration, in tenths of a second, modem waits after loss of carrier before
hanging up.

+007

S11=

Sets duration and spacing, in milliseconds, of dialed Touch-Tones.

+070

Table 4-16 Extended S-Registers "ATSn=x"

COMMAND BIT DEC HEX

FUNCTION

AND

DESCRIPTION

REF.

S13=

bit dec hex Bit-mapped

register.

+000

1

2

2

Capture modem manufacturer information during V.42
handshake, can be displayed at ATI2 <Last
Speed/Protocol> line if available (‘Flash’ or ‘ ZyXEL’
stands for ZyXEL connection)

S14=

bit dec hex Bit-mapped

register:

+002

1

0

0

Grant Remote Digital Loop-back test request.

&T4

2

2

Deny Remote Digital Loop-back test request. (Default)

&T5*

S15=

bit dec hex Bit-mapped

register.

+066