Leveling the appliance, Connecting to electricity supply, Warning – Zanussi ZKM6040 User Manual

Page 38

Advertising
background image

38

Curtains must not be fitted immediately
behind the appliance or within 150mm of the
sides of the hotplate. If fitted next to or
between two base units a minimum space of
2mm must be left between each unit and the
sides of the appliance. The levelling feet
fitted to the appliance will achieve a nominal
height to hotplate of 900mm + 20mm.

Leveling the appliance

Adjustment to suit floor conditions or height
is obtained by rotating clockwise or anti
clockwise the feet at the front and rear of the
appliance. A spirit level should be placed on
one of the shelves to confirm the appliance
is correctly leveled.

Connecting to electricity supply

WARNING!

Warning: This appliance must be earthed.
Do not earth this appliance to gas supply
piping. Connect to 230 - 240V AC supply
only.

Connection to the electricity supply must be
carried out by a qualified electrician/competent
person.

The electrical connection should be made
using a double pole isolating switch
(cooker socket) with at least 3mm contact
separation in all poles. The cable must
have conductors of sufficiently high cross-
sectional area to prevent overheating and
deterioration.

We recommend you use a new length of
6mm

2

twin core earthed cable to ensure

your safety.


Make connection by proceeding as follows:

L

L

N

N

N


Note: Blanking plates not to be removed.
Ensure that the links are fitted as shown

Pre-form wires to the appropriate shape to
suit fitting into the mains terminal block.

Strip inner insulation on wires using wire
strippers.

Twist the bared wires using pliers.

Cut bared wires 10mm away from the end
of the inner insulation.

Where uninsulated Earth wires are used
ensure they are suitably sheathed to leave
10mm bare wire to fit into the terminal.

Clamp bare wires into the relevant terminal
and check they are held by tugging each
one in turn.

Ensure all screws are securely tightened.

Clamp the mains cable securely ensuring
5mm of the outer insuation is inside the
terminal block and that the wires are not
taut but not so slack as to cause any
fouling.

Connect the remaining end of the mains
cable to the appliance to the appliance
point / junction box.

Place fuse / miniature circuit breaker in
circuit and switch on at mains.

When refitting the mains terminal cover,
ensure that the lower tabs are located
inside the bottom edge of the aperture,
before fixing the two screws into the top
edge of the mains terminal cover.

Advertising