Pressure testing, Checking the hob, Checking the lid shut-off device – Zanussi ZKM6040 User Manual

Page 40

Advertising
background image

40

1.

Place the appliance in its intended position
and level appliance.

2.

Mark a position 100mm from the top of the
rear right hand corner.

3.

Measure down 150mm from this point.
This gives the position of the wall anchor
point for the stability chain.

4.

The stability chain anchor point on the
appliance is shown below.





Pressure testing

1.

The Rapid injector is used as a pressure
test point.

2.

Connect the pressure gauge to the Rapid
injector.

3.

Check the supply pressure by turning the
Rapid burner on and one other hotplate
burner full on and light the appropriate
burner. The pressure should be 20mbar.

4.

Turn off the taps, disconnect the pressure
gauge.

5.

Check operation of each hotplate burner.

Checking the hob

1.

Lift the lid. Fit the burner crowns and caps
ensuring that they are correctly seated. Fit
the pan supports.

2.

Check each of the hob burners in turn by
turning the hob tap to its full on position and
pressing the ignition button. As soon as the
burners are lit the button can be released.

Checking the lid shut-off device

1.

Lift the lid

2.

Turn one hob tap to its full on position and
push the ignition button.

3.

Close the lid. There should now be no gas
supply to the hob and the burner will go
out.

4.

Turn off the hob and lift the lid. The gas
supply should now be restored to the hob,
when the tap is turned on.

To set the time of day

Please refer to the Timer section.

General note

Instruct the user on how to use the appliance
and its ignition system. Refer the user to the
wording inside this user manual which gives
advice on the safe operation of the
appliance.










Advertising