Zephyr CTP-E 60SX User Manual

Page 12

Advertising
background image

www.zephyronline.com

10

In

s

ta

lla

ti

o

n

-

P

re

p

a

rin

g

H

o

o

d

fo

r

E

xt

e

rn

a

l

B

lo

we

r

The external blower kit consists of an 8”
collar, external flange and external blower
wiring box. The external blower is purchased
separately.

ATTENTION

The following are instructions on preparing your hood for installation with external blower model CBE-1000.
For instructions on installing internal blower model CBI-600 please turn to page “8”.

1. P osition and attach external blower wiring
box and junction box using provided 1/2” self
tapping screws and 4mm internal diameter
washers.

2. Attach grounding wires from external
blower wiring box and junction box to
grounding screw as shown in Fig-A.

3. Position and attach external flange to
motor housing using provided 1/2” self
tapping screws.

4. Attach junction box and external blower
wiring box connectors to control board and
wiring box connectors inside hood.

Continue to page “11” for hood
installation instructions.